Objective intelligibility measurement of reverberant vocoded speech for normal-hearing listeners: Towards facilitating the development of speech enhancement algorithms for cochlear implants
The Journal of the Acoustical Society of America · 01.03.2024 · 155 (3) · 2151-2168
DOI: 10.1121/10.0025285 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, online erschienen am 19.03.2024. Verfasst von Lidea K Shahidi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27701, USA. Hauptthemen laut MEDLINE: Cochlear Implants, Cochlear Implantation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDCD NIH HHS, Graduate School, Duke University, National Institute on Deafness and Other Communication Disorders.
Abstract (Originalsprache)
Cochlear implant (CI) recipients often struggle to understand speech in reverberant environments. Speech enhancement algorithms could restore speech perception for CI listeners by removing reverberant artifacts from the CI stimulation pattern. Listening studies, either with cochlear-implant recipients or normal-hearing (NH) listeners using a CI acoustic model, provide a benchmark for speech intelligibility improvements conferred by the enhancement algorithm but are costly and time consuming. To reduce the associated costs during algorithm development, speech intelligibility could be estimated offline using objective intelligibility measures. Previous evaluations of objective measures that considered CIs primarily assessed the combined impact of noise and reverberation and employed highly accurate enhancement algorithms. To facilitate the development of enhancement algorithms, we evaluate twelve objective measures in reverberant-only conditions characterized by a gradual reduction of reverberant artifacts, simulating the performance of an enhancement algorithm during development. Measures are validated against the performance of NH listeners using a CI acoustic model. To enhance compatibility with reverberant CI-processed signals, measure performance was assessed after modifying the reference signal and spectral filterbank. Measures leveraging the speech-to-reverberant ratio, cepstral distance and, after modifying the reference or filterbank, envelope correlation are strong predictors of intelligibility for reverberant CI-processed speech.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27701, USA.
Förderung
- NIDCD NIH HHS
- Graduate School, Duke University
- National Institute on Deafness and Other Communication Disorders
Zitieren
APA
Shahidi, L. K., Collins, L. M., & Mainsah, B. O. (2024). Objective intelligibility measurement of reverberant vocoded speech for normal-hearing listeners: Towards facilitating the development of speech enhancement algorithms for cochlear implants. The Journal of the Acoustical Society of America, 155(3), 2151-2168. https://doi.org/10.1121/10.0025285
Vancouver
Shahidi LK, Collins LM, Mainsah BO. Objective intelligibility measurement of reverberant vocoded speech for normal-hearing listeners: Towards facilitating the development of speech enhancement algorithms for cochlear implants. The Journal of the Acoustical Society of America. 2024;155(3):2151-2168. doi:10.1121/10.0025285
BibTeX
@article{Shahidi2024,
author = {Shahidi, Lidea K and Collins, Leslie M and Mainsah, Boyla O},
title = {Objective intelligibility measurement of reverberant vocoded speech for normal-hearing listeners: Towards facilitating the development of speech enhancement algorithms for cochlear implants},
journal = {The Journal of the Acoustical Society of America},
year = {2024},
volume = {155},
number = {3},
pages = {2151--2168},
doi = {10.1121/10.0025285}
}