A simulation study on the sensitivity of transcranial ray-tracing ultrasound modeling to skull properties
The Journal of the Acoustical Society of America · 2023
DOI: 10.1121/10.0020761 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of the Acoustical Society of America, 2023. Verfasst von Robert Andrew Drainville und 5 weiteren Autor:innen. Beteiligte Einrichtung: LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France. Hauptthemen laut MEDLINE: Skull, Head. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Focused Ultrasound Foundation.
Abstract (Originalsprache)
In transcranial focused ultrasound therapies, such as treating essential tremor via thermal ablation in the thalamus, acoustic energy is focused through the skull using a phased-array transducer. Ray tracing is a computationally efficient method that can correct skull-induced phase aberrations via per-element phase delay calculations using patient-specific computed tomography (CT) data. However, recent studies show that variations in CT-derived Hounsfield unit may account for only 50% of the speed of sound variability in human skull specimens, potentially limiting clinical transcranial ultrasound applications. Therefore, understanding the sensitivity of treatment planning methods to material parameter variations is essential. The present work uses a ray-tracing simulation model to explore how imprecision in model inputs, arising from clinically significant uncertainties in skull properties or considerations of acoustic phenomena, affects acoustic focusing quality through the skull. We propose and validate new methods to optimize ray-tracing skull simulations for clinical treatment planning, relevant for predicting intracranial target's thermal rise, using experimental data from ex-vivo human skulls.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- LabTAU, INSERM, Centre Léon Bérard, Université Lyon 1, Univ Lyon, F-69003, Lyon, France.
- Université Paris-Saclay, CEA, List, F-91120, Palaiseau, France.
- Focused Ultrasound Foundation, Charlottesville, Virginia 22903, USA.
- Histosonics, Ann Arbor, Michigan 48103, USA.
ORCID-Profile: Robert Andrew Drainville, Sylvain Chatillon, John Snell, Frederic Padilla, Cyril Lafon
Förderung
- Focused Ultrasound Foundation
Zitieren
APA
Drainville, R. A., Chatillon, S., Moore, D., Snell, J., Padilla, F., & Lafon, C. (2023). A simulation study on the sensitivity of transcranial ray-tracing ultrasound modeling to skull properties. The Journal of the Acoustical Society of America. https://doi.org/10.1121/10.0020761
Vancouver
Drainville RA, Chatillon S, Moore D, Snell J, Padilla F, Lafon C. A simulation study on the sensitivity of transcranial ray-tracing ultrasound modeling to skull properties. The Journal of the Acoustical Society of America. 2023. doi:10.1121/10.0020761
BibTeX
@article{Drainville2023,
author = {Drainville, Robert Andrew and Chatillon, Sylvain and Moore, David and Snell, John and Padilla, Frederic and Lafon, Cyril},
title = {A simulation study on the sensitivity of transcranial ray-tracing ultrasound modeling to skull properties},
journal = {The Journal of the Acoustical Society of America},
year = {2023},
doi = {10.1121/10.0020761}
}
EUVIMED