EUVIMEDEUVIMED entdecken
Crossref

Numerical study of tilt aberration on heterodyne efficiency using partially coherent beam

Zhen Liu, Weibiao Chen

Optical Engineering · 23.02.2024 · 63 (02) · 1-13

DOI: 10.1117/1.oe.63.2.026104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optical Engineering, erschienen am 23.02.2024. Verfasst von Zhen Liu und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In a coherent Doppler wind lidar detection system, heterodyne efficiency is an extremely important parameter that reflects the matching degree between local oscillator (LO) light and signal light. More generally, assuming that both the LO light and signal light are partially coherent beams based on the Gaussian–Schell model, we have derived an analytical expression for the heterodyne efficiency in the presence of tilt aberration. The expression indicates that the heterodyne efficiency not only depends on the tilt aberration but also is influenced by the beam parameters, misalignment angle, detector diameter, and wavelength. Specific examples of the variation in heterodyne efficiency with these factors are given in the simulation section. The numerical results show that if high heterodyne efficiency is required, the intensity width of the LO light does not have to be large when the intensity width of the signal light is determined; besides, setting ws/wLO=0.5 is appropriate, where ws and wLO are the intensity width of signal and LO, respectively. Even if LO is a partially coherent beam, the heterodyne efficiency can still reach the global maximum of 0.86, and setting δs/δLO=0.6 is suitable, where δs and δLO are the coherence width of the signal and LO, respectively. As expected, the bigger the δs is, the higher the heterodyne efficiency is. For the same heterodyne efficiency, the tilt aberration can be larger slightly when the misalignment angle is small. We also find that the detector diameter plays a significant role in enhancing the heterodyne efficiency, and it is beneficial to choose a small detector diameter. Besides, the tilt aberration in the system should be less than 0.5λ. Moreover, we show that the rate of decrease in heterodyne efficiency with the tilt aberration is different for different misalignment angles. We also have demonstrated that the longer the wavelength, the higher the heterodyne efficiency for system with the same tilt aberration.

Zitieren

APA

Liu, Z., & Chen, W. (2024). Numerical study of tilt aberration on heterodyne efficiency using partially coherent beam. Optical Engineering, 63(02), 1-13. https://doi.org/10.1117/1.oe.63.2.026104

Vancouver

Liu Z, Chen W. Numerical study of tilt aberration on heterodyne efficiency using partially coherent beam. Optical Engineering. 2024;63(02):1-13. doi:10.1117/1.oe.63.2.026104

BibTeX
@article{Liu2024,
  author = {Liu, Zhen and Chen, Weibiao},
  title = {Numerical study of tilt aberration on heterodyne efficiency using partially coherent beam},
  journal = {Optical Engineering},
  year = {2024},
  volume = {63},
  number = {02},
  pages = {1--13},
  doi = {10.1117/1.oe.63.2.026104}
}
Kostenlos starten →