Monte Carlo simulations of time-resolved blood flow index: times-of-flight beyond ∼1 ns are necessary for brain-dominated measurements
Neurophotonics · 30.03.2026 · 13 (02) · 1-23
DOI: 10.1117/1.nph.13.2.025003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurophotonics, erschienen am 30.03.2026. Verfasst von Dominic W Hill und 18 weiteren Autor:innen. Beteiligte Einrichtung: CoMind Technologies, London, United Kingdom. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
SignificanceAchieving adequate brain sensitivity remains a significant obstacle to noninvasive optical measurements of pulsatile cerebral blood flow. Increasing source-detector separation (SDS), utilizing time-of-flight (ToF) information, and/or increasing acquisition frequency can increase brain sensitivity. However, optimizing these parameters is nontrivial and must balance the need to achieve sufficient signal-to-noise ratio.AimWe aim to guide hardware optimization by evaluating the benefits of ToF gating, autocorrelation time-lag gating, and increased source-detector separation in recovering pulsatile cerebral blood flow.ApproachMonte Carlo simulations of ToF-resolved pulsatile blood flow index at 1064 nm were performed. A simulation and analysis pipeline is presented and validated against phantom and in vivo measurements.ResultsBrain sensitivity deteriorates for autocorrelation time-lags >1 to 10 μs. Continuous-wave diffuse correlation spectroscopy (CW-DCS) at 40 mm SDS achieves equivalent brain sensitivity to time-resolved measurements with a 1.2 ns ToF gate. For median adult brain depths, a 31 mm SDS (CW-DCS), 35 mm SDS (speckle contrast optical spectroscopy), or 0.9 ns ToF are needed for brain-dominated signals. For the 85th percentile of brain depth, these thresholds increase to 40 mm, 46 mm, and 1.2 ns, respectively.ConclusionsWe quantitatively compare source-detector separation, ToF gating, and acquisition frequency and identify crucial performance requirements for clinically viable optical monitors of cerebral blood flow.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CoMind Technologies, London, United Kingdom.
- UCL, Department of Medical Physics and Biomedical Engineering, Biomedical Optics Research Laboratory, London, United Kingdom.
ORCID-Profile: Octave Etard, Alexandra Tran-Van-Minh, Pablo Villar Sanjurjo, Dawid Borycki, Matthew T Valley
Zitieren
APA
Hill, D. W., Behera, A., Etard, O., Zhang, Y., Tran-Van-Minh, A., Ruesch, A., Ness, L., Maine, C., Salehi Lashkajani, A., Parfentyeva, V., Singh, N., Antrobus, A., Prudden, R., Sanjurjo, P. V., Avtzi, S., Dragojević, T., Borycki, D., Valley, M. T., & Cooper, R. J. (2026). Monte Carlo simulations of time-resolved blood flow index: times-of-flight beyond ∼1 ns are necessary for brain-dominated measurements. Neurophotonics, 13(02), 1-23. https://doi.org/10.1117/1.nph.13.2.025003
Vancouver
Hill DW, Behera A, Etard O, Zhang Y, Tran-Van-Minh A, Ruesch A, et al. Monte Carlo simulations of time-resolved blood flow index: times-of-flight beyond ∼1 ns are necessary for brain-dominated measurements. Neurophotonics. 2026;13(02):1-23. doi:10.1117/1.nph.13.2.025003
BibTeX
@article{Hill2026,
author = {Hill, Dominic W and Behera, Anurag and Etard, Octave and Zhang, Yuqian and Tran-Van-Minh, Alexandra and Ruesch, Alexander and Ness, Lior and Maine, Chloe and Salehi Lashkajani, Amir and Parfentyeva, Veronika and Singh, Navjit and Antrobus, Alexander and Prudden, Rachel and Sanjurjo, Pablo Villar and Avtzi, Stella and Dragojević, Tanja and Borycki, Dawid and Valley, Matthew T and Cooper, Robert J},
title = {Monte Carlo simulations of time-resolved blood flow index: times-of-flight beyond ∼1 ns are necessary for brain-dominated measurements},
journal = {Neurophotonics},
year = {2026},
volume = {13},
number = {02},
pages = {1--23},
doi = {10.1117/1.nph.13.2.025003}
}
EUVIMED