Basis function model to extract the combined confocal and fall-off function from multiple optical coherence tomography A-scans
Journal of Biomedical Optics · 2025
DOI: 10.1117/1.jbo.30.2.025003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomedical Optics, 2025. Verfasst von Daniel J Phan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University, Vanderbilt Biophotonics Center, Department of Biomedical Engineering, Nashville, Tennessee, United States. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Image Processing, Computer-Assisted. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS.
Abstract (Originalsprache)
SignificanceMany derivatives of optical coherence tomography (OCT) rely on the depth-dependent information of the sample in the image. System depth-dependent effects, such as the confocal effect and the sensitivity fall-off, should be corrected to improve the accuracy of the images and information derived from them.AimWe developed a new single-shot method to extract the combined confocal and fall-off functions and remove system-generated depth-dependent effects from OCT images.ApproachThe combined function is modeled as a linear combination of basis functions whose coefficients are found from two or more A-scans (or B-scans) of a sample that are vertically shifted within the imaging range. No prior knowledge of the OCT system parameters or assumed form for the confocal and fall-off functions is needed.ResultsThe method was derived and validated with simulations and OCT images of a phantom, a biological sample, and human retina. Improvement over the Ratio Fit method was demonstrated.ConclusionsThe improvement in the extraction of the combined confocal and fall-off effects by this method should lead to improved medical diagnosis through more accurate attenuation coefficient calculations. The method enables future applications of OCT where precise removal of all depth-dependent effects on OCT images is critical.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Vanderbilt University, Vanderbilt Biophotonics Center, Department of Biomedical Engineering, Nashville, Tennessee, United States.
- Vanderbilt University Medical Center, Vanderbilt Institute for Global Health, Department of Biomedical Informatics and Medicine, Nashville, Tennessee, United States.
- Vanderbilt University Medical Center, Department of Pediatrics, Nashville, Tennessee, United States.
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States.
ORCID-Profile: Jörn-Hendrik Weitkamp, Audrey K Bowden
Förderung
- NIBIB NIH HHS
Zitieren
APA
Phan, D. J., Were, M., Weitkamp, J. H., & Bowden, A. K. (2025). Basis function model to extract the combined confocal and fall-off function from multiple optical coherence tomography A-scans. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.30.2.025003
Vancouver
Phan DJ, Were M, Weitkamp JH, Bowden AK. Basis function model to extract the combined confocal and fall-off function from multiple optical coherence tomography A-scans. Journal of Biomedical Optics. 2025. doi:10.1117/1.jbo.30.2.025003
BibTeX
@article{Phan2025,
author = {Phan, Daniel J and Were, Martin and Weitkamp, Jörn-Hendrik and Bowden, Audrey K},
title = {Basis function model to extract the combined confocal and fall-off function from multiple optical coherence tomography A-scans},
journal = {Journal of Biomedical Optics},
year = {2025},
doi = {10.1117/1.jbo.30.2.025003}
}
EUVIMED