Margin assessment during breast conserving surgery using diffuse reflectance spectroscopy
Journal of Biomedical Optics · 25.04.2024 · 29 (04) · 1-16
DOI: 10.1117/1.jbo.29.4.045006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomedical Optics, erschienen am 25.04.2024. Verfasst von Dinusha Veluponnar und 9 weiteren Autor:innen. Beteiligte Einrichtung: Netherlands Cancer Institute, Antoni van Leeuwenhoek, Department of Surgery, Image-Guided Surgery, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Breast Neoplasms, Mastectomy, Segmental, Margins of Excision, Spectrum Analysis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
SignificanceDuring breast-conserving surgeries, it is essential to evaluate the resection margins (edges of breast specimen) to determine whether the tumor has been removed completely. In current surgical practice, there are no methods available to aid in accurate real-time margin evaluation.AimIn this study, we investigated the diagnostic accuracy of diffuse reflectance spectroscopy (DRS) combined with tissue classification models in discriminating tumorous tissue from healthy tissue up to 2 mm in depth on the actual resection margin of in vivo breast tissue.ApproachWe collected an extensive dataset of DRS measurements on ex vivo breast tissue and in vivo breast tissue, which we used to develop different classification models for tissue classification. Next, these models were used in vivo to evaluate the performance of DRS for tissue discrimination during breast conserving surgery. We investigated which training strategy yielded optimum results for the classification model with the highest performance.ResultsWe achieved a Matthews correlation coefficient of 0.76, a sensitivity of 96.7% (95% CI 95.6% to 98.2%), a specificity of 90.6% (95% CI 86.3% to 97.9%) and an area under the curve of 0.98 by training the optimum model on a combination of ex vivo and in vivo DRS data.ConclusionsDRS allows real-time margin assessment with a high sensitivity and specificity during breast-conserving surgeries.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Netherlands Cancer Institute, Antoni van Leeuwenhoek, Department of Surgery, Image-Guided Surgery, Amsterdam, The Netherlands.
- University of Twente, Department of Nanobiophysics, Faculty of Science and Technology, Enschede, The Netherlands.
- Netherlands Cancer Institute, Antoni van Leeuwenhoek, Department of Pathology, Amsterdam, The Netherlands.
- Amsterdam University Medical Center, Department of Biomedical Engineering and Physics, Amsterdam, The Netherlands.
ORCID-Profile: Behdad Dashtbozorg, Lynn-Jade S Jong, Freija Geldof, Marcos Da Silva Guimaraes, Henricus J C M Sterenborg
Zitieren
APA
Veluponnar, D., de Boer, L. L., Dashtbozorg, B., Jong, L. S., Geldof, F., Guimaraes, M. D. S., Sterenborg, H. J. C. M., Vrancken-Peeters, M. T. F. D., van Duijnhoven, F., & Ruers, T. (2024). Margin assessment during breast conserving surgery using diffuse reflectance spectroscopy. Journal of Biomedical Optics, 29(04), 1-16. https://doi.org/10.1117/1.jbo.29.4.045006
Vancouver
Veluponnar D, de Boer LL, Dashtbozorg B, Jong LS, Geldof F, Guimaraes MDS, et al. Margin assessment during breast conserving surgery using diffuse reflectance spectroscopy. Journal of Biomedical Optics. 2024;29(04):1-16. doi:10.1117/1.jbo.29.4.045006
BibTeX
@article{Veluponnar2024,
author = {Veluponnar, Dinusha and de Boer, Lisanne L and Dashtbozorg, Behdad and Jong, Lynn-Jade S and Geldof, Freija and Guimaraes, Marcos Da Silva and Sterenborg, Henricus J C M and Vrancken-Peeters, Marie-Jeanne T F D and van Duijnhoven, Frederieke and Ruers, Theo},
title = {Margin assessment during breast conserving surgery using diffuse reflectance spectroscopy},
journal = {Journal of Biomedical Optics},
year = {2024},
volume = {29},
number = {04},
pages = {1--16},
doi = {10.1117/1.jbo.29.4.045006}
}
EUVIMED