EUVIMEDEUVIMED entdecken
Crossref

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

Tanmoy Chattopadhyay, Sven C. Herrmann, Matthew Kaplan, Peter Orel, Kevan Donlon, Gregory Y. Prigozhin, Glenn R. Morris, Michael J. Cooper, Andrew C. Malonis, Steven W. Allen, Marshall W. Bautz, Chris W. Leitz

Journal of Astronomical Telescopes, Instruments, and Systems · 15.05.2023 · 9 (02) · 1-11

DOI: 10.1117/1.jatis.9.2.026001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Astronomical Telescopes, Instruments, and Systems, erschienen am 15.05.2023. Verfasst von Tanmoy Chattopadhyay und 11 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Single-Electron Sensitive Read Out (SiSeRO) is an on-chip charge detector output stage for charge-coupled device image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source–drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge of around 15 electrons root mean square was obtained. In this work, we examine the first buried-channel SiSeRO. We have achieved substantially improved noise performance of around 4.5eRMS− and a full-width half-maximum energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel / s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting technology for the next-generation astronomical x-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

Zitieren

APA

Chattopadhyay, T., Herrmann, S. C., Kaplan, M., Orel, P., Donlon, K., Prigozhin, G. Y., Morris, G. R., Cooper, M. J., Malonis, A. C., Allen, S. W., Bautz, M. W., & Leitz, C. W. (2023). Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs. Journal of Astronomical Telescopes, Instruments, and Systems, 9(02), 1-11. https://doi.org/10.1117/1.jatis.9.2.026001

Vancouver

Chattopadhyay T, Herrmann SC, Kaplan M, Orel P, Donlon K, Prigozhin GY, et al. Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs. Journal of Astronomical Telescopes, Instruments, and Systems. 2023;9(02):1-11. doi:10.1117/1.jatis.9.2.026001

BibTeX
@article{Chattopadhyay2023,
  author = {Chattopadhyay, Tanmoy and Herrmann, Sven C. and Kaplan, Matthew and Orel, Peter and Donlon, Kevan and Prigozhin, Gregory Y. and Morris, Glenn R. and Cooper, Michael J. and Malonis, Andrew C. and Allen, Steven W. and Bautz, Marshall W. and Leitz, Chris W.},
  title = {Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs},
  journal = {Journal of Astronomical Telescopes, Instruments, and Systems},
  year = {2023},
  volume = {9},
  number = {02},
  pages = {1--11},
  doi = {10.1117/1.jatis.9.2.026001}
}
Kostenlos starten →