Development of an accurate cryogenic transmittance measurement system for the validation of immersion grating material of next-generation space telescopes
Journal of Astronomical Telescopes, Instruments, and Systems · 30.09.2025 · 11 (03) · 1-14
DOI: 10.1117/1.jatis.11.3.038003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Astronomical Telescopes, Instruments, and Systems, erschienen am 30.09.2025. Verfasst von Yuan Li und 9 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Grant-in-Aid for Scientific Research, JST SPRING.
Abstract (Originalsprache)
We are promoting a design of high-dispersion immersion grating for the high-resolution mid-infrared spectrometer (HRS, resolving power R≡λ/Δλ≈30,000 at λ=10 to 18 μm), which will be mounted onboard the next-generation infrared space telescope, Galaxy Reionization EXplorer and PLanetary Universe Spectrometer (GREX-PLUS). Compared with conventional diffraction gratings, immersion gratings reduce optical path length and the collimated mean diameter by a factor of 1/n, where n is the refractive index of the immersion material. Achieving such high spectral dispersion requires the use of highly transparent optical materials characterized by low absorption coefficients (α≤0.01 cm−1) at the instrument’s operating temperature (T≈20 K), to reduce instrumental background radiation. Cadmium Zinc Telluride (CdZnTe) has been identified as a promising candidate material, not only due to its low absorption coefficient but also due to its machinability. Recent transmittance measurements conducted by Maeshima et al. at cryogenic temperatures indicated that high-resistivity CdZnTe exhibits superior optical properties suitable for immersion gratings, in contrast to low-resistivity CdZnTe. To precisely determine the absorption coefficient of high-resistivity CdZnTe, we developed a cryogenic common-path double-beam transmittance measurement system with an original design. Utilizing a filament lamp placed within the vacuum chamber, combined with three bandpass filters, we achieved transmittance measurement precision better than 0.06% across a continuous temperature range from room temperature to 5.7 K. Employing recently published refractive index data, we derived absorption coefficients (α) at T≈20 K of 0.00049, 0.00333, and 0.00251 cm−1 for wavelengths of 10.6, 15.1, and 19.0 μm, respectively. Notably, the absorption coefficient for high-resistivity CdZnTe exhibited minimal temperature dependence and remained consistently below 0.01 cm−1, satisfying the stringent optical requirements for GREX-PLUS HRS.
Förderung
- Grant-in-Aid for Scientific Research
- JST SPRING
Zitieren
APA
Li, Y., Hirahara, Y., Koga, R., Zhao, B., Sasago, H., Nakagawa, T., Matsuhara, H., Baba, S., Enokidani, U., & Wada, T. (2025). Development of an accurate cryogenic transmittance measurement system for the validation of immersion grating material of next-generation space telescopes. Journal of Astronomical Telescopes, Instruments, and Systems, 11(03), 1-14. https://doi.org/10.1117/1.jatis.11.3.038003
Vancouver
Li Y, Hirahara Y, Koga R, Zhao B, Sasago H, Nakagawa T, et al. Development of an accurate cryogenic transmittance measurement system for the validation of immersion grating material of next-generation space telescopes. Journal of Astronomical Telescopes, Instruments, and Systems. 2025;11(03):1-14. doi:10.1117/1.jatis.11.3.038003
BibTeX
@article{Li2025,
author = {Li, Yuan and Hirahara, Yasuhiro and Koga, Ryoichi and Zhao, Biao and Sasago, Hiroshi and Nakagawa, Takao and Matsuhara, Hideo and Baba, Shunsuke and Enokidani, Umi and Wada, Takehiro},
title = {Development of an accurate cryogenic transmittance measurement system for the validation of immersion grating material of next-generation space telescopes},
journal = {Journal of Astronomical Telescopes, Instruments, and Systems},
year = {2025},
volume = {11},
number = {03},
pages = {1--14},
doi = {10.1117/1.jatis.11.3.038003}
}