Demonstration of low-order wavefront sensing and control system of Roman coronagraph instrument in thermal vacuum testing environment

Byoung-Joon Seo, Nanaz Fathpour, David P. Arndt, Joel F. Shields, Dhemetrios Boussalis, Eric J. Cady, Brian D. Kern

Journal of Astronomical Telescopes, Instruments, and Systems · 17.06.2025 · 11 (02) · 1-28

DOI: 10.1117/1.jatis.11.2.021411 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Astronomical Telescopes, Instruments, and Systems, erschienen am 17.06.2025. Verfasst von Byoung-Joon Seo und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Aeronautics and Space Administration.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prior to its delivery to the Goddard Space Flight Center (GSFC) on May 17, 2024, the integrated coronagraph instrument (CGI) underwent testing and verification at the Jet Propulsion Laboratory. We detail the test outcomes of the focus control loop (FCL) and Zernike control loop (ZCL) in the CGI’s thermal vacuum (TVAC) test environment. To obtain and maintain the required wavefront stability, the CGI features a dedicated subsystem, the low-order wavefront sensing and control (LOWFSC), which detects wavefront alterations using starlight reflected off the focal plane mask, converts these changes into Zernike modes Z2-Z11, and independently controls Z2/Z3, Z4, and Z5-Z11 through three distinct control loops: line of sight control loop (LCL), FCL, and ZCL. Unlike the LCL, the testing of FCL and ZCL has been unfeasible without an appropriate testbed equipped with the necessary optical stimuli. Thus, the CGI TVAC tests mark the first system-level evaluation of FCL and ZCL prior to the CGI’s handover to GSFC. The tests and subsequent analysis affirm that both loops are operating as intended, successfully meeting the key requirements of CGI. This document delineates various test configurations, presents the collected data, and scrutinizes the resulting outcomes. In addition, it includes the dark hole contrast data acquired through the exoplanetary systems camera (EXCAM). By concurrently measuring the EXCAM dark hole images alongside the LOWFSC observation, we were able to assess the CGI’s contrast sensitivity to the Zernike wavefront errors, though the accuracy of these measurements suffered from unintentional partial saturation of the dark hole images.

Förderung

  • National Aeronautics and Space Administration

Zitieren

APA

Seo, B., Fathpour, N., Arndt, D. P., Shields, J. F., Boussalis, D., Cady, E. J., & Kern, B. D. (2025). Demonstration of low-order wavefront sensing and control system of Roman coronagraph instrument in thermal vacuum testing environment. Journal of Astronomical Telescopes, Instruments, and Systems, 11(02), 1-28. https://doi.org/10.1117/1.jatis.11.2.021411

Vancouver

Seo B, Fathpour N, Arndt DP, Shields JF, Boussalis D, Cady EJ, et al. Demonstration of low-order wavefront sensing and control system of Roman coronagraph instrument in thermal vacuum testing environment. Journal of Astronomical Telescopes, Instruments, and Systems. 2025;11(02):1-28. doi:10.1117/1.jatis.11.2.021411

BibTeX
@article{Seo2025,
  author = {Seo, Byoung-Joon and Fathpour, Nanaz and Arndt, David P. and Shields, Joel F. and Boussalis, Dhemetrios and Cady, Eric J. and Kern, Brian D.},
  title = {Demonstration of low-order wavefront sensing and control system of Roman coronagraph instrument in thermal vacuum testing environment},
  journal = {Journal of Astronomical Telescopes, Instruments, and Systems},
  year = {2025},
  volume = {11},
  number = {02},
  pages = {1--28},
  doi = {10.1117/1.jatis.11.2.021411}
}