Adjustable X-ray optics: thin-film actuator measurement and figure correction performance
Journal of Astronomical Telescopes, Instruments, and Systems · 02.08.2024 · 10 (03) · 1-27
DOI: 10.1117/1.jatis.10.3.039003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Astronomical Telescopes, Instruments, and Systems, erschienen am 02.08.2024. Verfasst von Kenneth Buffo und 10 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
Several proposed future X-ray missions will require thin (≤0.5 mm thick) mirrors with precise surface figures to maintain high angular resolution (≤0.5 arcsec). To study methods of meeting these requirements, adjustable X-ray optics have been fabricated with thin-film piezoelectric actuators to perform figure correction. The fabrication and actuator performance for an adjustable X-ray mirror that forms a conical approximation to a Wolter-I telescope are reported. The individual responses of actuator cells were measured and shown to induce a figure change of 870 nm peak-to-valley on average. These measured responses were compared with predicted responses generated using a finite-element analysis algorithm. On average, the measured and predicted cell responses agreed to within 60 nm root mean square. A set of representative mirror distortions and the measured cell responses were used to simulate figure corrections and calculate the half-power diameter (HPD, single reflection at 1 keV) achieved. These simulations showed an improvement in 4.5 to 9 arcsec mirrors to 0.5 to 1.5 arcsec HPD. The disagreements between the predicted and measured cells’ performance in actuation and figure correction were attributed to a high spatial frequency metrology error and differences in mirror bonding considerations between the finite-element analysis model and the as-built mirror mount.
Zitieren
APA
Buffo, K., DeRoo, C., Reid, P., Kradinov, V., Marquez, V., Trolier-McKinstry, S., Bishop, N., Jackson, T. N., Tran, Q., Liang, H., & Tendulkar, M. (2024). Adjustable X-ray optics: thin-film actuator measurement and figure correction performance. Journal of Astronomical Telescopes, Instruments, and Systems, 10(03), 1-27. https://doi.org/10.1117/1.jatis.10.3.039003
Vancouver
Buffo K, DeRoo C, Reid P, Kradinov V, Marquez V, Trolier-McKinstry S, et al. Adjustable X-ray optics: thin-film actuator measurement and figure correction performance. Journal of Astronomical Telescopes, Instruments, and Systems. 2024;10(03):1-27. doi:10.1117/1.jatis.10.3.039003
BibTeX
@article{Buffo2024,
author = {Buffo, Kenneth and DeRoo, Casey and Reid, Paul and Kradinov, Vladimir and Marquez, Vanessa and Trolier-McKinstry, Susan and Bishop, Nathan and Jackson, Thomas N. and Tran, Quyen and Liang, Hanyuan and Tendulkar, Mohit},
title = {Adjustable X-ray optics: thin-film actuator measurement and figure correction performance},
journal = {Journal of Astronomical Telescopes, Instruments, and Systems},
year = {2024},
volume = {10},
number = {03},
pages = {1--27},
doi = {10.1117/1.jatis.10.3.039003}
}