EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning

Olivia I Kolenc iD, Divya M Gollapalli iD, Alan E Woessner iD, Jocelyn Martinez iD, Alex J Walsh iD, Kyle P Quinn iD

Biophotonics Discovery · 11.11.2026 · 3 (04) · 1-15

DOI: 10.1117/1.bios.3.4.045001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biophotonics Discovery, erschienen am 11.11.2026. Verfasst von Olivia I Kolenc und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

SignificanceFluorescence lifetime imaging (FLIM) analysis commonly involves multi-exponential fitting of fluorescence decays, which requires relatively high signal-to-noise ratios (SNRs). However, autofluorescence presents a weaker signal compared with exogenous fluorophores, which can make fitting challenging. Becker & Hickl’s SPCImage (SPCI) is commonly used for bi-exponential fitting of NAD(P)H autofluorescence decays, but its accuracy has not been robustly evaluated.AimWe evaluate the accuracy of bi-exponential modeling of NAD(P)H FLIM data from live cells and provide an alternative fitting algorithm that allows for photon binning of whole cells for low SNR applications.ApproachSimulated fluorescence lifetime decay data and NADH solutions were used to test the accuracy of fitting in both SPCI and a custom-written MATLAB algorithm. FLIM images collected from live cells using varying integration times were also evaluated.ResultsResults show consistently higher error for SPCI in fluorescence decay parameters compared with the custom-written MATLAB algorithm. Whole-cell binning greatly improved the accuracy of all lifetime decay parameters, allowing for shorter integration times during acquisition.ConclusionsOur custom-written MATLAB algorithm can provide a flexible alternative fitting tool that allows for photon binning of whole cells and substantially more accurate parameter estimation.

Schlagwörter

Stichwörter der Autor:innen

NADHautofluorescencefluorescence lifetime imagingmetabolic imagingmultiphoton microscopy

Autor:innen und Institutionen

  • University of Arkansas, Department of Biomedical Engineering, Fayetteville, Arkansas, United States.
  • Tufts University, Department of Biomedical Engineering, Medford, Massachusetts, United States.
  • Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States.

ORCID-Profile: Olivia I Kolenc, Divya M Gollapalli, Alan E Woessner, Jocelyn Martinez, Alex J Walsh, Kyle P Quinn

Förderung

  • U.S. National Science Foundation

Zitieren

APA

Kolenc, O. I., Gollapalli, D. M., Woessner, A. E., Martinez, J., Walsh, A. J., & Quinn, K. P. (2026). Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning. Biophotonics Discovery, 3(04), 1-15. https://doi.org/10.1117/1.bios.3.4.045001

Vancouver

Kolenc OI, Gollapalli DM, Woessner AE, Martinez J, Walsh AJ, Quinn KP. Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning. Biophotonics Discovery. 2026;3(04):1-15. doi:10.1117/1.bios.3.4.045001

BibTeX
@article{Kolenc2026,
  author = {Kolenc, Olivia I and Gollapalli, Divya M and Woessner, Alan E and Martinez, Jocelyn and Walsh, Alex J and Quinn, Kyle P},
  title = {Improving bi-exponential fitting of autofluorescence lifetime decay data through whole-cell binning},
  journal = {Biophotonics Discovery},
  year = {2026},
  volume = {3},
  number = {04},
  pages = {1--15},
  doi = {10.1117/1.bios.3.4.045001}
}
Kostenlos starten →