EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of skin tone on target size detectability in photoacoustic breast imaging

Rhea D Rasquinha iD, Mardava R Gubbi iD, Muyinatu A Lediju Bell iD

Biophotonics Discovery · 2024

DOI: 10.1117/1.bios.2.1.012502 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biophotonics Discovery, 2024. Verfasst von Rhea D Rasquinha und 2 weiteren Autor:innen. Beteiligte Einrichtung: Brown University, Department of Biomedical Engineering, Providence, Rhode Island, United States. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

SignificancePhotoacoustic imaging has the potential to improve non-invasive breast cancer diagnosis. However, illumination through the skin introduces a skin tone bias, as greater melanin content increases optical absorption and can create acoustic clutter, reducing the visibility of various target sizes.AimWe investigate the impact of skin tone bias as a function of target sizes in three photoacoustic image reconstruction methods: fast Fourier transform (FFT)-based reconstruction, delay-and-sum (DAS) beamforming, and short-lag spatial coherence (SLSC) beamforming.MethodsThe three imaging methods were applied to channel data from multidomain simulations with 757, 800, and 1064 nm wavelengths, 11 target sizes (ranging 0.5 to 3 mm), 18 skin tones [ranging individual typology angles (ITAs), of –54 deg to 60 deg], and a previously validated realistic 3D breast model. The signal-to-noise ratio (SNR) and generalized contrast-to-noise ratio (gCNR) were measured to assess visibility.ResultsWith 757 and 800 nm wavelengths, targets underlying dark skin tones (ITA range: −54 deg to −33 deg) with sizes ≤3 mm were poorly visible with ≤2.38 to 4.21 mean SNR and ≤0.46 to 0.74 mean gCNR, with smaller targets generally being more visible with lighter skin tones. A 1064-nm transmit wavelength improved visualization with DAS and SLSC beamforming, relative to both FFT reconstruction with a 1064 nm wavelength and DAS or SLSC beamforming with 757 and 800 nm wavelengths. When combined with SLSC beamforming, the 1064-nm wavelength offered the greatest improvements, enabling visualization of simulated target sizes ranging from 0.5 to 3 mm underlying very light (ITA = 60 deg) to dark (ITA=−54 deg) skin tones, with mean SNR ≤10.01 and mean gCNR ≤1. Visualization of simulated vessel structures derived from in vivo photoacoustic images was consistent with simulation-based target size expectations.ConclusionsResults are promising for advancing next-generation photoacoustic imaging systems for breast cancer diagnosis across the range of skin tones represented in healthcare systems throughout the world.

Schlagwörter

Stichwörter der Autor:innen

acoustic clutterbreast imagingcoherence-based beamformingphotoacoustic imagingtarget visibility

Autor:innen und Institutionen

  • Brown University, Department of Biomedical Engineering, Providence, Rhode Island, United States.
  • Johns Hopkins University, Department of Electrical and Computer Engineering, Baltimore, Maryland, United States.
  • Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
  • Johns Hopkins University, Department of Computer Science, Baltimore, Maryland, United States.
  • Johns Hopkins Medicine, Department of Oncology, Baltimore, Maryland, United States.

ORCID-Profile: Rhea D Rasquinha, Mardava R Gubbi, Muyinatu A Lediju Bell

Förderung

  • NIBIB NIH HHS

Zitieren

APA

Rasquinha, R. D., Gubbi, M. R., & Lediju Bell, M. A. (2024). Impact of skin tone on target size detectability in photoacoustic breast imaging. Biophotonics Discovery. https://doi.org/10.1117/1.bios.2.1.012502

Vancouver

Rasquinha RD, Gubbi MR, Lediju Bell MA. Impact of skin tone on target size detectability in photoacoustic breast imaging. Biophotonics Discovery. 2024. doi:10.1117/1.bios.2.1.012502

BibTeX
@article{Rasquinha2024,
  author = {Rasquinha, Rhea D and Gubbi, Mardava R and Lediju Bell, Muyinatu A},
  title = {Impact of skin tone on target size detectability in photoacoustic breast imaging},
  journal = {Biophotonics Discovery},
  year = {2024},
  doi = {10.1117/1.bios.2.1.012502}
}
Kostenlos starten →