Optimization and development of a compact NIR-RGB Mueller matrix imaging polarimeter: application to in situ skin measurements
Advanced Photonics Nexus · 03.03.2026 · 5 (02) · 1-14
DOI: 10.1117/1.apn.5.2.026009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Photonics Nexus, erschienen am 03.03.2026. Verfasst von Iván Montes-González und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación and Fondos FEDER, Generalitat de Catalunya.
Abstract (Originalsprache)
We report the design and implementation of a portable Mueller matrix imaging polarimeter for fast in situ assessment of skin. The system integrates a polarization state generator, composed of a linear polarizer and two liquid-crystal variable retarders, with a compact polarization state analyzer formed by a liquid-crystal retarder and a division-of-focal-plane polarimetric camera. The setup operates at four discrete wavelengths (470, 554, 630, and 730 nm), enabling the evaluation of polarization signatures over the visible and near-infrared range, relevant for dermatological and biomedical diagnostics. A complete optical model was developed to quantify polarization effects of each element and to identify a measurement scheme that minimizes error propagation and maximizes signal-to-noise ratio while retrieving the full 4×4 Mueller matrix from only eight acquisitions. Calibration was performed via a generalized eigenvalue method, achieving robust compensation of system imperfections. The instrument’s performance was first validated through numerical simulations and then through imaging of reference optical elements and preliminary tissue images, demonstrating accurate, spatially resolved Mueller matrix measurements. These results highlight the potential of the proposed system as a practical tool for portable, noninvasive polarimetric imaging in clinical and research environments.
Förderung
- Ministerio de Ciencia e Innovación and Fondos FEDER
- Generalitat de Catalunya
Zitieren
APA
Montes-González, I., Bisbal, J., Li, D., Canabal-Carbia, M., Campos, J., Estévez, I., & Lizana, A. (2026). Optimization and development of a compact NIR-RGB Mueller matrix imaging polarimeter: application to in situ skin measurements. Advanced Photonics Nexus, 5(02), 1-14. https://doi.org/10.1117/1.apn.5.2.026009
Vancouver
Montes-González I, Bisbal J, Li D, Canabal-Carbia M, Campos J, Estévez I, et al. Optimization and development of a compact NIR-RGB Mueller matrix imaging polarimeter: application to in situ skin measurements. Advanced Photonics Nexus. 2026;5(02):1-14. doi:10.1117/1.apn.5.2.026009
BibTeX
@article{MontesGonzlez2026,
author = {Montes-González, Iván and Bisbal, Judit and Li, Dekui and Canabal-Carbia, Monica and Campos, Juan and Estévez, Irene and Lizana, Angel},
title = {Optimization and development of a compact NIR-RGB Mueller matrix imaging polarimeter: application to in situ skin measurements},
journal = {Advanced Photonics Nexus},
year = {2026},
volume = {5},
number = {02},
pages = {1--14},
doi = {10.1117/1.apn.5.2.026009}
}