Off-axis compressed encoding microscopy for high-resolution, high-throughput, high-contrast volumetric imaging
Advanced Photonics · 09.11.2026 · 9 (01) · 1-16
DOI: 10.1117/1.ap.9.1.016004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Photonics, erschienen am 09.11.2026. Verfasst von Dejie Zhang und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
High-throughput volumetric fluorescence microscopy requires depth-dependent information to be preserved while maintaining lateral resolution, optical-sectioning contrast, and acquisition speed. Here, we introduce off-axis compressed encoding microscopy (OCEM), a volumetric imaging method that encodes depth-dependent information directly into accelerated two-dimensional measurements. OCEM achieves physics-defined depth encoding: the illumination profile and off-axis multiline detection geometry generate detector-row-specific intensity fingerprints that vary with axial position. These fingerprints provide depth constraints directly in the acquired measurements, enabling a lightweight decoder to recover depth-resolved volumes with optical-sectioning contrast. OCEM combines 4× axial compression with 4× lateral acceleration, achieving a 16-fold increase in volumetric acquisition throughput based on camera exposure time. Because the encoding is implemented within the existing off-axis detection geometry, OCEM requires no additional beam splitters, cameras, or detection paths. We validate OCEM in whole-brain imaging and volumetric FISH, demonstrating preserved structural continuity, optical-sectioning contrast, and signal-localization consistency for large-scale quantitative biological imaging.
Zitieren
APA
Zhang, D., Jiang, T., & Gong, H. (2026). Off-axis compressed encoding microscopy for high-resolution, high-throughput, high-contrast volumetric imaging. Advanced Photonics, 9(01), 1-16. https://doi.org/10.1117/1.ap.9.1.016004
Vancouver
Zhang D, Jiang T, Gong H. Off-axis compressed encoding microscopy for high-resolution, high-throughput, high-contrast volumetric imaging. Advanced Photonics. 2026;9(01):1-16. doi:10.1117/1.ap.9.1.016004
BibTeX
@article{Zhang2026,
author = {Zhang, Dejie and Jiang, Tao and Gong, Hui},
title = {Off-axis compressed encoding microscopy for high-resolution, high-throughput, high-contrast volumetric imaging},
journal = {Advanced Photonics},
year = {2026},
volume = {9},
number = {01},
pages = {1--16},
doi = {10.1117/1.ap.9.1.016004}
}
EUVIMED