Ultra-rapid and reusable luminescent gas sensor based on MAPbX3 quantum dots nano-confined in glass
Advanced Photonics · 02.01.2026 · 8 (01) · 1-11
DOI: 10.1117/1.ap.8.1.016006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Photonics, erschienen am 02.01.2026. Verfasst von Kai Feng und 13 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: “Pioneer” and “Leading Goose” R&D Program of Zhejiang, National Natural Science Foundation of China, Zhejiang Provincial Natural Science Foundation.
Abstract (Originalsprache)
Detecting hazardous hydrogen halides (HX, X = Cl, Br, and I) gas is critical for human health and ecological safety. A luminescent sensor based on anion exchange reaction (AER) in perovskite could offer a cost-effective approach. However, resolving the challenging issues of instability and the acceleration requirement of AER is highly desired for practical applications. Here, we develop an ultra-rapid, sensitive, and reusable HCl luminescent gas sensor through nanoconfining MAPbBr3 quantum dots (QDs) into a transparent nanoporous glass (NG) matrix, successfully extending perovskite glass to the organic–inorganic system, which exhibits enhanced AER sensitivity. Utilizing enhanced transport efficiency of reactants within NG, HCl gas could be rapidly adsorbed into the nanopores and undergo ultra-rapid AER with the embedded perovskite QDs. In addition, the device stability could be fostered by the physical protection of glass matrix. After being simply integrated with UV LED, the MAPbBr3-NG exhibits an ultra-rapid response time within 2 s at a HCl gas concentration of 5 ppm. Furthermore, this luminescent gas sensor demonstrates robust performance, retaining functionality over 10 reuse cycles. This compact, cost-effective, and highly sensitive device with rapid response capability could open a promising avenue for research on HX detection while expanding the practical applications of perovskite-based devices.
Förderung
- “Pioneer” and “Leading Goose” R&D Program of Zhejiang
- National Natural Science Foundation of China
- Zhejiang Provincial Natural Science Foundation
- Shanghai Pilot Program for Basic Research
Zitieren
APA
Feng, K., Zhou, F., Wang, C., Wu, D., Zhan, Z., Lu, Q., Hu, Z., Yang, Y., He, J., Zhang, L., Zhang, Z., Liu, Z., Leng, Y., & Du, J. (2026). Ultra-rapid and reusable luminescent gas sensor based on MAPbX3 quantum dots nano-confined in glass. Advanced Photonics, 8(01), 1-11. https://doi.org/10.1117/1.ap.8.1.016006
Vancouver
Feng K, Zhou F, Wang C, Wu D, Zhan Z, Lu Q, et al. Ultra-rapid and reusable luminescent gas sensor based on MAPbX3 quantum dots nano-confined in glass. Advanced Photonics. 2026;8(01):1-11. doi:10.1117/1.ap.8.1.016006
BibTeX
@article{Feng2026,
author = {Feng, Kai and Zhou, Fengxian and Wang, Chunwei and Wu, Daqian and Zhan, Zijun and Lu, Qixuan and Hu, Zhiping and Yang, Yingguo and He, Jin and Zhang, Long and Zhang, Zeyu and Liu, Zhengzheng and Leng, Yuxin and Du, Juan},
title = {Ultra-rapid and reusable luminescent gas sensor based on MAPbX3 quantum dots nano-confined in glass},
journal = {Advanced Photonics},
year = {2026},
volume = {8},
number = {01},
pages = {1--11},
doi = {10.1117/1.ap.8.1.016006}
}