EUVIMEDEUVIMED entdecken
Crossref

Precision plasma sterilization system integrating machine vision and Z-axis closed-loop distance control

Le Dong, Shuang-Long Wang, Zheng-Yan Chen, Hui-Juan Lu, Guang-Xiu Peng, Xiao-Qiong Wang, Xiao-Xia Du, Hua Li

Journal of Vacuum Science & Technology B · 01.09.2026 · 44 (5)

DOI: 10.1116/6.0005538 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vacuum Science & Technology B, online erschienen am 27.07.2026. Verfasst von Le Dong und 7 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Gefördert von: Natural Science Foundation of Guangxi Zhuang Autonomous Region, National Natural Science Foundation of China, Guilin University of Electronic Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To mitigate active-species flux attenuation and localized treatment blind spots caused by variations in jet-to-surface distance during atmospheric-pressure low-temperature plasma treatment of three-dimensional nonplanar targets, we developed a precision plasma-treatment system integrating machine vision, field-programmable gate array-based trajectory planning, and Z-axis closed-loop laser distance control. The field-programmable gate array handled target-boundary extraction and scan-trajectory generation, while a tilted laser displacement sensor, a spatial geometric compensation model, and a segmented-velocity closed-loop strategy corrected Z-axis deviations in real time and maintained a 10 mm standoff distance. Static tests showed a Z-axis distance-control error of ±0.04 mm, and dynamic step-response tests converged within 500 ms. In a representative scan with repeated ±0.5 mm step disturbances, the measured standoff distance was 10.00 ± 0.18 mm, with an instantaneous range of 9.49–10.52 mm, and the system returned to within ±0.1 mm in approximately 400 ms after each disturbance. Starch-potassium iodide visualization indicated a distance-dependent spatial distribution of plasma-induced oxidative effects. In three independent biological replicates, Escherichia coli plate experiments showed pronounced distance-dependent attenuation in the conventional fixed-height mode, whereas Z-axis closed-loop scanning maintained 99.4%–100.0% sterilization efficiency across all tested regions and geometries. The corresponding log-reduction values, including detection-limit lower bounds for plates with no recovered colonies, were consistent with these results. These findings show that real-time standoff-distance compensation improves treatment uniformity on nonplanar model surfaces and supports the system as a precision plasma-treatment engineering platform for future plasma-medicine studies.

Förderung

  • Natural Science Foundation of Guangxi Zhuang Autonomous Region
  • National Natural Science Foundation of China
  • Guilin University of Electronic Technology
  • National College Students Innovation and Entrepreneurship Training Program

Zitieren

APA

Dong, L., Wang, S., Chen, Z., Lu, H., Peng, G., Wang, X., Du, X., & Li, H. (2026). Precision plasma sterilization system integrating machine vision and Z-axis closed-loop distance control. Journal of Vacuum Science & Technology B, 44(5). https://doi.org/10.1116/6.0005538

Vancouver

Dong L, Wang S, Chen Z, Lu H, Peng G, Wang X, et al. Precision plasma sterilization system integrating machine vision and Z-axis closed-loop distance control. Journal of Vacuum Science & Technology B. 2026;44(5). doi:10.1116/6.0005538

BibTeX
@article{Dong2026,
  author = {Dong, Le and Wang, Shuang-Long and Chen, Zheng-Yan and Lu, Hui-Juan and Peng, Guang-Xiu and Wang, Xiao-Qiong and Du, Xiao-Xia and Li, Hua},
  title = {Precision plasma sterilization system integrating machine vision and Z-axis closed-loop distance control},
  journal = {Journal of Vacuum Science & Technology B},
  year = {2026},
  volume = {44},
  number = {5},
  doi = {10.1116/6.0005538}
}
Kostenlos starten →