EUVIMEDEUVIMED entdecken
Crossref

Development of a mesh nebulizer for high-yield generation of 1–5 μ m aerosols

Taki Watanabe, Sho Amano, Yuichi Utsumi, Kazuhiro Kanda

Journal of Vacuum Science & Technology B · 01.07.2026 · 44 (4)

DOI: 10.1116/6.0005416 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vacuum Science & Technology B, online erschienen am 29.05.2026. Verfasst von Taki Watanabe und 3 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Japan Science and Technology Agency.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid atomization is a key factor in inhalation therapy because it determines where inhaled aerosols deposit within the respiratory tract. Delivery to the deep lung generally requires aerosol generation in the range of 1–5 μm. However, current medical nebulizers often struggle to produce aerosols in this size range at high yield and tend to generate an undesirable coarse aerosol fraction. In mesh nebulizers, which are compact, quiet, and increasingly used in clinical settings, the nozzle-aperture diameter governs the resulting aerosol size. In this study, we fabricated nozzle-array filters with submicrometer-to-few-micrometer apertures—which are difficult to realize via conventional methods—using multistep exposure x-ray lithography, and demonstrated high-yield generation of 1–5 μm aerosols with a mesh nebulizer. We fabricated filters with mean aperture diameters of 7.5, 2.3, and 1.6 μm at NewSUBARU BL11 and evaluated them using a commercial piezoelectric oscillator unit. Laser diffraction measurements showed that the median aerosol diameter decreased systematically with aperture diameter, from 12.5 to 4.8 and 3.2 μm, with the smallest-aperture filter producing aerosols predominantly within the target 1–5 μm range for inhalation therapy. We also examined the dependence of nebulization performance on liquid properties and confirmed stable aerosol generation within the 1–5 μm range for a clinically relevant aqueous formulation. These results establish a practical route to 1–5 μm aerosol generation through aperture-controlled nozzle-array design and x-ray lithography-based fabrication.

Förderung

  • Japan Science and Technology Agency

Zitieren

APA

Watanabe, T., Amano, S., Utsumi, Y., & Kanda, K. (2026). Development of a mesh nebulizer for high-yield generation of 1–5 μ m aerosols. Journal of Vacuum Science & Technology B, 44(4). https://doi.org/10.1116/6.0005416

Vancouver

Watanabe T, Amano S, Utsumi Y, Kanda K. Development of a mesh nebulizer for high-yield generation of 1–5 μ m aerosols. Journal of Vacuum Science & Technology B. 2026;44(4). doi:10.1116/6.0005416

BibTeX
@article{Watanabe2026,
  author = {Watanabe, Taki and Amano, Sho and Utsumi, Yuichi and Kanda, Kazuhiro},
  title = {Development of a mesh nebulizer for high-yield generation of 1–5 μ m aerosols},
  journal = {Journal of Vacuum Science & Technology B},
  year = {2026},
  volume = {44},
  number = {4},
  doi = {10.1116/6.0005416}
}
Kostenlos starten →