EUVIMEDEUVIMED entdecken
Crossref

Analysis of a Clinically Failed, Mechanically Intact, Hemi-Toe Implant

Swetha Varadharajan, Shingo Okamoto, Richard Laughlin, Laughlin Goswami

Journal of Biomedical Engineering and Biosciences · 2016

DOI: 10.11159/jbeb.2016.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomedical Engineering and Biosciences, 2016. Verfasst von Swetha Varadharajan und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this case study a clinically failed, mechanically intact, hemi-toe device was investigated.The clinical indication of the failure constitutes radiolucent line indicating loosening of the implant and possible interactions among the boneimplant initiated by osteolysis may become a factor, producing pain, inflammatory reactions, deformity and discomfort.The patient file was not available to determine these parameters.The device was titanium coated, Cobalt Chromium alloy used for making hemi-toe.Degeneration of hemi implant was due to spalling of the coating from the surface, causing loosening of stem from bone.However, pre-removal X-ray films were not available to confirm.Mechanism by which the clinical failure occurred likely due to lack of bony adhesion or other clinical reasons.Surface topographical features were documented using optical microscope.A method to classify various area of the articulating surface was proposed in this study that shows the anterior contacts were more damaging than the other areas where deeper scratches, pits and some debris were present.There is a need to converge mechanical and clinical failures together for these types of medical devices.

Zitieren

APA

Varadharajan, S., Okamoto, S., Laughlin, R., & Goswami, L. (2016). Analysis of a Clinically Failed, Mechanically Intact, Hemi-Toe Implant. Journal of Biomedical Engineering and Biosciences. https://doi.org/10.11159/jbeb.2016.005

Vancouver

Varadharajan S, Okamoto S, Laughlin R, Goswami L. Analysis of a Clinically Failed, Mechanically Intact, Hemi-Toe Implant. Journal of Biomedical Engineering and Biosciences. 2016. doi:10.11159/jbeb.2016.005

BibTeX
@article{Varadharajan2016,
  author = {Varadharajan, Swetha and Okamoto, Shingo and Laughlin, Richard and Goswami, Laughlin},
  title = {Analysis of a Clinically Failed, Mechanically Intact, Hemi-Toe Implant},
  journal = {Journal of Biomedical Engineering and Biosciences},
  year = {2016},
  doi = {10.11159/jbeb.2016.005}
}
Kostenlos starten →