EUVIMEDEUVIMED entdecken
ÄquivalenzstudieVergleichsstudie

AI landmark versus conventional ultrasound-guided injections for adhesive capsulitis: a prospective, propensity score-matched, superiority study

Xiaohong Cui, Wen Cao, Yongliang Liu

Medical Ultrasonography · 2025

DOI: 10.11152/mu-4557 ↗

Kurz gefasst

Äquivalenzstudie in der Zeitschrift Medical Ultrasonography, 2025. Verfasst von Xiaohong Cui und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pain Management, Sinopharm Harbin General Hospital, Harbin City. Hauptthemen laut MEDLINE: Bursitis, Ultrasonography, Interventional.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To investigate the artificial Intelligence (AI) landmark for guiding rotator cuff interval injections for adhesive capsulitis (AC).Material and methods: One hundred fifty-five patients undergoing AI landmark-guided injections were prospectively enrolled (AI cohort). A 1:1 propensity-score matching was conducted for ultrasound (US) cohort receiving US-guided injections (n=149). The primary endpoint was shoulder pain and disability index (SPADI) scores at 1-month post-injections, with a defined superiority margin of a 10-point decrease. Secondary outcomes included needle insertions, procedure time, range off motion, quality of life (QoL) and adverse events.

Results

SPADI scores at 1-month follow-up was 32.81±18.16 and 44.53±11.74 in two cohorts with a mean difference of -11.72 (95%CI: -17.95, -10.48), confirming the superiority (p=0.025). Higher means were observed at 1-week and 3-month post-injections (p=0.018 and 0.033). Better improvements were observed in forward flexion (158.77±13.12 vs. 145.97±11.49, p=0.016), abduction (78.98±15.96 vs. 61.09±17.09, p=0.007) and external rotation (63.13±19.97 vs. 50.19±13.85, p=0.019) in AI cohort compared to US cohort at 1-week post-injections. AI cohort had fewer needle insertions, shorter procedure times and better QoL scores. Minor adverse events were observed.

Conclusions

AI approach facilitated the identification of shoulder landmarks and demonstrated superiority in relieving shoulder pain and improving function compared to ultrasound method.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BursitisUltrasonography, InterventionalHumansFemaleProspective StudiesMaleInjections, Intra-ArticularMiddle AgedPropensity ScoreTreatment OutcomeIntelligent SystemsShoulder PainAgedRotator CuffRange of Motion, Articular

Autor:innen und Institutionen

  • Department of Pain Management, Sinopharm Harbin General Hospital, Harbin City.
  • Department of Medical Ultrasonics, Capital Medical University Affiliated Beijing Chaoyang Hospital, Beijing.
  • Department of Pain Management, Hongqi Hospital Affiliated to Mudanjing Medical University, Mudanjiang City. zsylzs123@163.com.

Zitieren

APA

Cui, X., Cao, W., & Liu, Y. (2025). AI landmark versus conventional ultrasound-guided injections for adhesive capsulitis: a prospective, propensity score-matched, superiority study. Medical Ultrasonography. https://doi.org/10.11152/mu-4557

Vancouver

Cui X, Cao W, Liu Y. AI landmark versus conventional ultrasound-guided injections for adhesive capsulitis: a prospective, propensity score-matched, superiority study. Medical Ultrasonography. 2025. doi:10.11152/mu-4557

BibTeX
@article{Cui2025,
  author = {Cui, Xiaohong and Cao, Wen and Liu, Yongliang},
  title = {AI landmark versus conventional ultrasound-guided injections for adhesive capsulitis: a prospective, propensity score-matched, superiority study},
  journal = {Medical Ultrasonography},
  year = {2025},
  doi = {10.11152/mu-4557}
}
Kostenlos starten →