EUVIMEDEUVIMED entdecken
Crossref

Diagnostic performance of PET-CT and technical efficacy of ultrasound-guided core needle biopsy of small and intermediate size malignant supraclavicular lymph nodes

Woo Hee Choi, Jiwon Bae, Jae Ho Shin

Medical Ultrasonography · 2024

DOI: 10.11152/mu-4447 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Ultrasonography, 2024. Verfasst von Woo Hee Choi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Nuclear Medicine, Department of Radiology, St. Vincent's Hospital, The Catholic University of Korea, Suwon si. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Lymph Nodes, Image-Guided Biopsy, Ultrasonography, Interventional.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

We aimed (1) to determine optimal PET-CT SUV and ultrasound (US) features associated for malignant smallintermediate size supraclavicular lymph nodes (SCN) and (2) to evaluate technical efficacy of core needle biopsy (CNB). Materials and methods: Between 2020 and 2023, CNB of SCN with short-axis less than 15 mm were included. PET-CT was evaluated for optimal SUV cut-off value. Multivariate logistic regression was performed for US features. Technical efficacy of CNB (success rate) was calculated, and US features were compared between satisfactory CNB specimen and unsatisfactory CNB specimen.

Results

Eighty-four SCN per 80 patients (age 64.0±17.2 years, 45.2% female) were included. The optimal SUV cut-off value was 1.1 with diagnostic accuracy of 89.8%. US features associated with malignancy were anteroposterior dimension ≥9 mm and absence of hilum. The overall CNB success rate was 94%, and unsatisfactory specimen demonstrated shorter transverse diameter (12 mm vs 5 mm, p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyLymph NodesImage-Guided BiopsyUltrasonography, InterventionalLymphatic MetastasisHumansFemaleMiddle AgedMaleBiopsy, Large-Core NeedleAgedRetrospective StudiesReproducibility of ResultsAdult

Autor:innen und Institutionen

  • Division of Nuclear Medicine, Department of Radiology, St. Vincent's Hospital, The Catholic University of Korea, Suwon si.
  • Department of Radiology, St. Vincent's Hospital, The Catholic University of Korea, Suwon si.
  • Department of Radiology, Korea University Anam Hospital, Seoul. Shinjh@kumc.or.kr.

Zitieren

APA

Choi, W. H., Bae, J., & Shin, J. H. (2024). Diagnostic performance of PET-CT and technical efficacy of ultrasound-guided core needle biopsy of small and intermediate size malignant supraclavicular lymph nodes. Medical Ultrasonography. https://doi.org/10.11152/mu-4447

Vancouver

Choi WH, Bae J, Shin JH. Diagnostic performance of PET-CT and technical efficacy of ultrasound-guided core needle biopsy of small and intermediate size malignant supraclavicular lymph nodes. Medical Ultrasonography. 2024. doi:10.11152/mu-4447

BibTeX
@article{Choi2024,
  author = {Choi, Woo Hee and Bae, Jiwon and Shin, Jae Ho},
  title = {Diagnostic performance of PET-CT and technical efficacy of ultrasound-guided core needle biopsy of small and intermediate size malignant supraclavicular lymph nodes},
  journal = {Medical Ultrasonography},
  year = {2024},
  doi = {10.11152/mu-4447}
}
Kostenlos starten →