Utrasound as a method for confirming the positioning of enteral catheters in critically ill patients
Medical Ultrasonography · 2024
DOI: 10.11152/mu-4392 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Medical Ultrasonography, 2024. Verfasst von Ronan De Souza und 7 weiteren Autor:innen. Beteiligte Einrichtung: Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina In…. Hauptthemen laut MEDLINE: Critical Illness. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
Aim
To evaluate the agreement between the bedside ultrasound in a single epigastric window and the plain X-ray to confirm the positioning of the enteral catheter in critically ill patients.Material and methods: This was an observational, cross-sectional study conducted in two Intensive Care Units of a university hospital. The ultrasound exams were carried out immediately after the introduction of the enteral catheter, using only the epigastric window, with an injection of 5 ml of air associated with 5 ml of saline solution. In all cases, the plain radiography was taken to confirm the positioning of the enteral catheter and to define the beginning of nutritional therapy.
Results
This study included 83 patients, the positioning of the enteral catheter was confirmed by plain radiography in all cases and by ultrasound in 81 (97.6%) patients. The median duration of the ultrasound exam was 2 (2-3) minutes, while the time spent between the request for the X-ray and the release of the exam for a doctor’s appointment was 225 (120-330) minutes.
Conclusion
Bedside ultrasound proved to be an effective, quick, and safe method to confirm the position of the enteral catheter in critically ill patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil. ronansolza@yahoo.com.b…
- Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, Bed Management Team, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investiga…
- Internal Medicine Department, School of Medicine, Universidade Federal de Minas Gerais, Brazil.
- Bed Management Team, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil.
- Internal Medicine Department, School of Medicine, Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil.
- Intensive Care Unit, Hospital das Clínicas of the Universidade Federal de Minas Gerais, NIIMI (Núcleo Interdisciplinar de Investigação em Medicina Intensiva), Belo Horizonte, Minas Gerais, Brazil.
Zitieren
APA
De Souza, R., Ravetti, C. G., Silva E Castro, R., Frossard, E. F., Dos Anjos, I. S., Dos Reis Gomes, A. G., Vassallo, P. F., & Nobre, V. (2024). Utrasound as a method for confirming the positioning of enteral catheters in critically ill patients. Medical Ultrasonography. https://doi.org/10.11152/mu-4392
Vancouver
De Souza R, Ravetti CG, Silva E Castro R, Frossard EF, Dos Anjos IS, Dos Reis Gomes AG, et al. Utrasound as a method for confirming the positioning of enteral catheters in critically ill patients. Medical Ultrasonography. 2024. doi:10.11152/mu-4392
BibTeX
@article{DeSouza2024,
author = {De Souza, Ronan and Ravetti, Cecilia Gómez and Silva E Castro, Rafael and Frossard, Elio Furbino and Dos Anjos, Isabella Santanna and Dos Reis Gomes, Angélica Gomides and Vassallo, Paula Frizera and Nobre, Vandack},
title = {Utrasound as a method for confirming the positioning of enteral catheters in critically ill patients},
journal = {Medical Ultrasonography},
year = {2024},
doi = {10.11152/mu-4392}
}
EUVIMED