Beobachtungsstudie in der Zeitschrift Medical Ultrasonography, online erschienen am 17.02.2019. Verfasst von Enrico Maria Zardi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hospitalist Service, Campus Bio-Medico University, Rome, Italy. e.zardi@unicampus.it. Die Arbeit wurde bisher 25-mal zitiert (Crossref).
Abstract (Originalsprache)
Aim
The aim of this work was to evaluate the reliability of pSWE in assessing the stiffness of the vastus medialis muscle and of the quadriceps and patellar tendons.Material and methods: For this purpose, 18 subjects (9 males and 9 females of 57±22 years) in good clinical conditions were included in this study. pSWE examination was conducted by a unique expert operator with more than ten years of experience in musculoskeletal ultrasound. Two sets of five measurements for each muscle and tendon district were bilaterally performed at the same manner, at least fifteen minutes apart. The mean value of the measurements of each set was statistically compared with that of the other set.
Results
No significant differences were found comparing the mean value of the measurements of the two sets of evaluation performed in muscle and tendon areas (vastus medialis muscle: p=0.285; quadriceps tendon: p=0.979; patellar tendon: p=0.187). The intraclass correlation coefficient was excellent for all areas (vastus medialis muscle: 0.969; quadriceps and patellar tendons: 0.995 and 0.989, respectively).
Conclusion
The pSWE technique demonstrated that it was a reliable method for measuring stiffness in vastus medialis muscle and quadriceps and patellar tendon in subjects who had undergone orthopedic surgery. This opens the possibility of many applications in monitoring stiffness before and after surgery and during rehabilitation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Hospitalist Service, Campus Bio-Medico University, Rome, Italy. e.zardi@unicampus.it.
- Upper and Lower Limb Surgery Unit, University Campus Bio-Medico, Rome. e.franceschetti@unicampus.it.
- Radiology, S. Maria della Misericordia Hospital, Urbino. giorgi.chiara@sanita.marche.it.
- Upper and Lower Limb Surgery Unit, University Campus Bio-Medico, Rome. a.palumbo@unicampus.it.
- Upper and Lower Limb Surgery Unit, University Campus Bio-Medico, Rome. f.franceschi@unicampus.it.
Zitieren
APA
Zardi, E. M., Franceschetti, E., Giorgi, C., Palumbo, A., & Franceschi, F. (2019). Reliability of quantitative point shear-wave ultrasound elastography on vastus medialis muscle and quadriceps and patellar tendons. Medical Ultrasonography, 21(1), 50. https://doi.org/10.11152/mu-1712
Vancouver
Zardi EM, Franceschetti E, Giorgi C, Palumbo A, Franceschi F. Reliability of quantitative point shear-wave ultrasound elastography on vastus medialis muscle and quadriceps and patellar tendons. Medical Ultrasonography. 2019;21(1):50. doi:10.11152/mu-1712
BibTeX
@article{Zardi2019,
author = {Zardi, Enrico Maria and Franceschetti, Edoardo and Giorgi, Chiara and Palumbo, Alessio and Franceschi, Francesco},
title = {Reliability of quantitative point shear-wave ultrasound elastography on vastus medialis muscle and quadriceps and patellar tendons},
journal = {Medical Ultrasonography},
year = {2019},
volume = {21},
number = {1},
pages = {50},
doi = {10.11152/mu-1712}
}
EUVIMED