EUVIMEDEUVIMED entdecken
Crossref

Assessment of Energy Savings Using Run-Around Coil Heat Recovery in Air Conditioning Systems: A Fresh-Exhaust Air Analysis

A. Abdel-Fattah, M. Abd El-Baky, M. Gad El-Rab, A.-F. Mahrous

ASME Journal of Engineering for Sustainable Buildings and Cities · 01.11.2026 · 7 (4)

DOI: 10.1115/1.4072767 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ASME Journal of Engineering for Sustainable Buildings and Cities, online erschienen am 04.11.2026. Verfasst von A. Abdel-Fattah und 3 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Medical laboratories, chemical facilities, hospitals, and commercial buildings require large volumes of conditioned fresh air, creating substantial annual cooling loads. Because these spaces operate at high ventilation air-change rates (ACH), exhaust air heat recovery has become essential for reducing energy use and greenhouse gas emissions. Among available heating, ventilation, and air conditioning (HVAC) strategies, the run-around coil is widely adopted to transfer thermal energy between two independent fluid circuits and recover heat from supply and exhaust airflows. This study experimentally evaluates a run-around coil system that precools fresh air using cooled return air. The effects of fresh air inlet temperature, cooled air inlet temperature, mass flowrate ratio, and coil diameter on temperature reduction and heat exchanger effectiveness were investigated. Results show that fresh air inlet temperature is the dominant factor: higher inlet temperatures consistently increase the fresh air temperature difference (ΔT1) and enhance heat exchanger effectiveness. Effectiveness peaks when the exhaust-to-fresh mass flowrate ratio is near or slightly greater than unity, whereas lower ratios reduce the temperature difference or limit heat transfer. Coil geometry also plays a critical role. A larger fresh air coil paired with a smaller exhaust-side coil (d1 = 14.28 mm, d2 = 7.9 mm) produces the greatest temperature change, whereas reversing these sizes yields the smallest. These findings demonstrate that maintaining a warm freshair inlet, balancing flow rates, and selecting coil diameters to match flow capacity can substantially improve system efficiency. The results confirm the run-around coil as an effective approach for reducing energy consumption and environmental impact in high-load ventilation environments.

Zitieren

APA

Abdel-Fattah, A., El-Baky, M. A., El-Rab, M. G., & Mahrous, A. (2026). Assessment of Energy Savings Using Run-Around Coil Heat Recovery in Air Conditioning Systems: A Fresh-Exhaust Air Analysis. ASME Journal of Engineering for Sustainable Buildings and Cities, 7(4). https://doi.org/10.1115/1.4072767

Vancouver

Abdel-Fattah A, El-Baky MA, El-Rab MG, Mahrous A. Assessment of Energy Savings Using Run-Around Coil Heat Recovery in Air Conditioning Systems: A Fresh-Exhaust Air Analysis. ASME Journal of Engineering for Sustainable Buildings and Cities. 2026;7(4). doi:10.1115/1.4072767

BibTeX
@article{AbdelFattah2026,
  author = {Abdel-Fattah, A. and El-Baky, M. Abd and El-Rab, M. Gad and Mahrous, A.-F.},
  title = {Assessment of Energy Savings Using Run-Around Coil Heat Recovery in Air Conditioning Systems: A Fresh-Exhaust Air Analysis},
  journal = {ASME Journal of Engineering for Sustainable Buildings and Cities},
  year = {2026},
  volume = {7},
  number = {4},
  doi = {10.1115/1.4072767}
}
Kostenlos starten →