Transient Forced Response of a Mistuned Blisk Rotor in a Multistage Axial Compressor
Journal of Turbomachinery · 01.11.2026 · 148 (11)
DOI: 10.1115/1.4072756 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Turbomachinery, online erschienen am 19.10.2026. Verfasst von Yujun Leng und 3 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Rotor forced response is a major aeromechanical problem causing blade high-cycle fatigue, and mistuning can significantly increase the maximum blade vibrational amplitude due to mode localization. Most previous mistuned forced response experimental studies were conducted at slow rotational speed sweep rates through the resonance and analyzed using the steady-state assumption. However, in practice, engine sweep rate can be significantly high such that the classical steady-state forced response analysis becomes invalid. To study the transient forced response in a realistic environment, a comprehensive experimental study was conducted in the Purdue three-stage axial research compressor by measuring rotor blade response at four different sweep rates in both acceleration and deceleration. An overall peak amplitude reduction and peak frequency shift were observed at higher sweep rates, along with a transient beating occurring at the highest sweep rate. Initially, an analytical transient analysis for a single-degree-of-freedom (SDOF) system was conducted. While it explains the major features of the transient response well, it fails to accurately predict the amplitude change at different sweep rates. The transient effect differences measured between acceleration and deceleration are also completely missed by the SDOF analysis. Therefore, a transient mistuned rotor analysis was performed utilizing the fundamental mistuning model (FMM). Through a mode superposition approach, the transient mistuned rotor analysis shows that the difference measured in the acceleration and deceleration cases was caused by the relative phase change of the dominant modes contributing to the total resonant response.
Zitieren
APA
Leng, Y., Matthews, D. R., Dodda, J. R., & Key, N. L. (2026). Transient Forced Response of a Mistuned Blisk Rotor in a Multistage Axial Compressor. Journal of Turbomachinery, 148(11). https://doi.org/10.1115/1.4072756
Vancouver
Leng Y, Matthews DR, Dodda JR, Key NL. Transient Forced Response of a Mistuned Blisk Rotor in a Multistage Axial Compressor. Journal of Turbomachinery. 2026;148(11). doi:10.1115/1.4072756
BibTeX
@article{Leng2026,
author = {Leng, Yujun and Matthews, Douglas R. and Dodda, Jhansi R. and Key, Nicole L.},
title = {Transient Forced Response of a Mistuned Blisk Rotor in a Multistage Axial Compressor},
journal = {Journal of Turbomachinery},
year = {2026},
volume = {148},
number = {11},
doi = {10.1115/1.4072756}
}