Decoupling the Roles of Conductivity, Architecture, and Pore Diameter in Transpiration Cooling Through Sintered Metallic Porous Media
Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy · 01.12.2026 · 2 (12)
DOI: 10.1115/1.4072749 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy, online erschienen am 30.10.2026. Verfasst von Md Tarif Raihan und 1 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
Transpiration cooling through sintered metallic porous media is a promising active thermal-protection strategy for high-heat-flux aerospace and propulsion applications, yet the relative influence of the solid material, the pore architecture, and the pore diameter on cooling performance has not been established within a single, internally consistent framework. This study presents a combined experimental and numerical investigation that decouples and ranks these three parameters. Four sintered porous specimens—comprising a titanium powder, a sintered SS316L powder, and SS316L wire mesh at pore diameters of 80 and 100 µm—were tested in a rectangular channel over a Reynolds-number range of 38,000–70,000, with cooling effectiveness, surface temperature, and pressure drop measured across a nine-point thermal-imaging grid. A two-dimensional local thermal nonequilibrium (LTNE) Darcy–Forchheimer model employing physically based inertial coefficients, with no calibration against the thermal data, was developed to interpret the measurements. The results establish a clear sensitivity hierarchy in which solid thermal conductivity exerts the dominant influence, pore architecture exerts a secondary influence, and pore diameter exerts a comparatively minor influence: the titanium specimen attained cooling effectiveness values of 0.77–0.88 against 0.567–0.677 for the SS316L wire mesh, the isotropic sintered powder outperformed the anisotropic wire mesh, and the difference between the 80 µm and 100 µm meshes was limited to approximately 2.3%. The model reproduced the measured cooling effectiveness with a root-mean-square error of 0.090 while recovering physically consistent injection velocities and revealed that the classical Kozeny–Carman relation over-predicts the permeability of consolidated woven meshes by up to two orders of magnitude—identifying the effective permeability as the principal source of residual model uncertainty. The combined findings yield validated design guidance for transpiration-cooled components, prioritizing high-conductivity matrices and isotropic pore architectures, and identify direct permeametry as the key measurement required to render the flow closure fully predictive.
Zitieren
APA
Raihan, M. T., & Amano, R. S. (2026). Decoupling the Roles of Conductivity, Architecture, and Pore Diameter in Transpiration Cooling Through Sintered Metallic Porous Media. Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy, 2(12). https://doi.org/10.1115/1.4072749
Vancouver
Raihan MT, Amano RS. Decoupling the Roles of Conductivity, Architecture, and Pore Diameter in Transpiration Cooling Through Sintered Metallic Porous Media. Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy. 2026;2(12). doi:10.1115/1.4072749
BibTeX
@article{Raihan2026,
author = {Raihan, Md Tarif and Amano, Ryoichi S.},
title = {Decoupling the Roles of Conductivity, Architecture, and Pore Diameter in Transpiration Cooling Through Sintered Metallic Porous Media},
journal = {Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy},
year = {2026},
volume = {2},
number = {12},
doi = {10.1115/1.4072749}
}
EUVIMED