On the Mechanics of Bioimpedance Signals Under Deformation

Chihtong Lee, William Chan Santos, Carmina Andrade, Raudel Avila

Journal of Applied Mechanics · 01.12.2026 · 93 (12)

DOI: 10.1115/1.4072745 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Mechanics, online erschienen am 14.10.2026. Verfasst von Chihtong Lee und 3 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Gefördert von: American Heart Association, Rice University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bioimpedance provides a noninvasive means of characterizing biological tissues and monitoring physiological function. In wearable and skin-integrated systems, however, electrical measurements are acquired while the underlying tissues undergo extension, bending, twisting, compression, and physiological motion. These deformations alter the conducting domain, electrode placement, and redistribute the three-dimensional current field. The measured impedance, therefore, reflects both the tissue's electrical properties and its mechanical state, yet the mechanics governing this dependence remain poorly understood. Here, we combine tetrapolar measurements on conductive hydrogel phantoms, coupled mechanics and electrical finite element analysis, and reduced-order theory to determine how distinct deformation modes enter the impedance response. Deformation alone produces systematic impedance changes reaching approximately 30% under extension, 5% under bending, and 3% under torsion. These relations reproduce the experimental means with root-mean-square errors below 1.2 percentage points and demonstrate that response magnitude is governed by the order at which deformation perturbs electrically weighted current paths, rather than by the apparent complexity of the deformation field. Finite element calculations further show that, for uniform and variable conductivity, conductivity sets the absolute impedance scale while deformation produces a distinct normalized geometric offset. Small conductivity uncertainties can nevertheless equal or exceed the complete bending and torsional signals, and this separation breaks down when conductivity varies spatially or evolves during deformation. These findings establish mechanics as a governing state variable in bioimpedance and provide a basis for distinguishing deformation-induced signals from physiological changes in wearable measurements of highly deformable tissues.

Förderung

  • American Heart Association
  • Rice University

Zitieren

APA

Lee, C., Santos, W. C., Andrade, C., & Avila, R. (2026). On the Mechanics of Bioimpedance Signals Under Deformation. Journal of Applied Mechanics, 93(12). https://doi.org/10.1115/1.4072745

Vancouver

Lee C, Santos WC, Andrade C, Avila R. On the Mechanics of Bioimpedance Signals Under Deformation. Journal of Applied Mechanics. 2026;93(12). doi:10.1115/1.4072745

BibTeX
@article{Lee2026,
  author = {Lee, Chihtong and Santos, William Chan and Andrade, Carmina and Avila, Raudel},
  title = {On the Mechanics of Bioimpedance Signals Under Deformation},
  journal = {Journal of Applied Mechanics},
  year = {2026},
  volume = {93},
  number = {12},
  doi = {10.1115/1.4072745}
}
Kostenlos starten →