Constrained Optimization of a Large-Diameter Static Mixer for Hydrogen-Blended Natural Gas Using Response Surface Methodology
Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy · 01.09.2026 · 2 (9)
DOI: 10.1115/1.4072432 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy, online erschienen am 13.08.2026. Verfasst von Xiaolong Gu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Hydrogen blending into natural-gas pipelines is a practical transitional pathway for large-scale hydrogen transport using existing infrastructure, but direct injection can cause concentration non-uniformity and increasing operational and safety risks. In this study, a large-diameter SK-type static mixer for hydrogen-blended pipelines was numerically investigated under operating conditions derived from the Shaanxi–Beijing Gas Pipeline I, and its geometry was optimized using a response-surface-based constrained optimization method. The effects of five geometric parameters, namely the number of mixing elements, element thickness, length-to-diameter ratio, helix angle, and inter-element spacing, on mixing non-uniformity and pressure drop were first analyzed systematically. Plackett–Burman screening and Box–Behnken response surface modeling were then employed to identify dominant factors and determine an optimized mixer geometry. The results show that the number of mixing elements, length-to-diameter ratio, and helix angle are dominant parameters affecting both mixing performance and pressure drop. Increasing the number of elements and helix angle, or decreasing the length-to-diameter ratio, improves mixing but increases pressure drop, whereas appropriate inter-element spacing can enhance mixing while reducing pressure drop. The optimized mixer consists of three elements with 10 mm thickness, length-to-diameter ratio 0.842, helix angle 120 deg, and inter-element spacing 0.4D. Evaluation of the injection arrangement shows that an insertion depth of 0.1D yields the best overall performance. Under the investigated conditions, this configuration keeps the coefficient of variation below 5% within 5D downstream.
Zitieren
APA
Gu, X., Xiong, Z., Zhang, X., Wang, Q., & Yang, Y. (2026). Constrained Optimization of a Large-Diameter Static Mixer for Hydrogen-Blended Natural Gas Using Response Surface Methodology. Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy, 2(9). https://doi.org/10.1115/1.4072432
Vancouver
Gu X, Xiong Z, Zhang X, Wang Q, Yang Y. Constrained Optimization of a Large-Diameter Static Mixer for Hydrogen-Blended Natural Gas Using Response Surface Methodology. Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy. 2026;2(9). doi:10.1115/1.4072432
BibTeX
@article{Gu2026,
author = {Gu, Xiaolong and Xiong, Zhiyi and Zhang, Xin and Wang, Qianbing and Yang, Yunnan},
title = {Constrained Optimization of a Large-Diameter Static Mixer for Hydrogen-Blended Natural Gas Using Response Surface Methodology},
journal = {Journal of Energy Resources Technology, Part A: Sustainable and Renewable Energy},
year = {2026},
volume = {2},
number = {9},
doi = {10.1115/1.4072432}
}
EUVIMED