Integrating Liquid-to-Air Sidecars in High-Power Data Centers: Challenges and Best Practices

Vahideh Radmard, Farzaneh Hosseini, Ali Heydari, Mohammad Tradat, Saket Karajgikar, Dwayne Kalma, Bahgat Sammakia

Journal of Electronic Packaging · 01.12.2026 · 148 (4)

DOI: 10.1115/1.4072185 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electronic Packaging, online erschienen am 10.07.2026. Verfasst von Vahideh Radmard und 6 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rapid growth of AI workloads has pushed rack power densities to unprecedented levels, testing the limits of legacy air-cooled data centers. Liquid-to-air (L2A) sidecar coolant distribution units (CDUs) have emerged as a practical, cost-effective solution for enabling rack deployments exceeding 125 kW without requiring major infrastructure changes. However, their scalability and reliability in real-world environments remain constrained by operational challenges such as air leakage, flow sensor drift, fan speed oscillations, and delayed redundancy activation. To address these limitations, we conducted a systematic experimental investigation of L2A CDU performance under high-load conditions. Our testing demonstrated the reliability risks associated with these limitations. Air leakage induced supply air temperature (SAT) variations from 20.9 °C to 27.6 °C, while pump failover delays of approximately 10 s resulted in transient case temperature spikes exceeding 130 °C. To mitigate these risks, we implemented and validated targeted solutions, including ultrasonic flow sensing, predictive fan control algorithms, and dual-active pump configurations. Ultimately, these results provide a practical roadmap for reducing deployment risks and improving system resilience. As AI data centers continue to scale toward megawatt-class rack power levels, this work highlights the critical factors necessary for a safe transition from hybrid cooling to next-generation, liquid-focused thermal architectures.

Zitieren

APA

Radmard, V., Hosseini, F., Heydari, A., Tradat, M., Karajgikar, S., Kalma, D., & Sammakia, B. (2026). Integrating Liquid-to-Air Sidecars in High-Power Data Centers: Challenges and Best Practices. Journal of Electronic Packaging, 148(4). https://doi.org/10.1115/1.4072185

Vancouver

Radmard V, Hosseini F, Heydari A, Tradat M, Karajgikar S, Kalma D, et al. Integrating Liquid-to-Air Sidecars in High-Power Data Centers: Challenges and Best Practices. Journal of Electronic Packaging. 2026;148(4). doi:10.1115/1.4072185

BibTeX
@article{Radmard2026,
  author = {Radmard, Vahideh and Hosseini, Farzaneh and Heydari, Ali and Tradat, Mohammad and Karajgikar, Saket and Kalma, Dwayne and Sammakia, Bahgat},
  title = {Integrating Liquid-to-Air Sidecars in High-Power Data Centers: Challenges and Best Practices},
  journal = {Journal of Electronic Packaging},
  year = {2026},
  volume = {148},
  number = {4},
  doi = {10.1115/1.4072185}
}
Kostenlos starten →