EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Evaluation of Subcooled Pool Boiling Performance Using Novec 7000 and Water in a Taper Microgap Boiling Chamber

Nooruldeen E. Mustafa, Satish G. Kandlikar

ASME Journal of Heat and Mass Transfer · 01.09.2026 · 148 (9)

DOI: 10.1115/1.4072138 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ASME Journal of Heat and Mass Transfer, online erschienen am 15.07.2026. Verfasst von Nooruldeen E. Mustafa und 1 weiteren Autor:innen. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A comparative experimental investigation of subcooled pool boiling heat transfer performance was conducted using 3M Novec 7000 (HFE-7000) near atmospheric pressure (1 atm, Tsat = 34 °C) and de-ionized water at subatmospheric pressure (12 kPa, Tsat ≈ 49 °C) in a compact boiling chamber with submerged condensation. The chamber incorporates an enhanced finned-tube condenser and dual-taper microgap manifolds over microchannel-enhanced copper substrates. Four open microchannels were tested. For Novec 7000, the highest critical heat flux (CHF) of 51.4 W/cm2 was achieved in the 762 μm channel and taper microgap at 20 °C coolant, indicating a 38% enhancement over the no-taper baseline. At a coolant inlet temperature of 40 °C, the same configuration reached approximately 66 W/cm2, the highest value reported for HFE-7000 on any surface area above 1 cm2. At 12 kPa, the 381 μm microchannel without taper achieved 185.3 W/cm2. Increasing the coolant inlet temperature from 20 °C to 45 °C in the 381 μm taper configuration raised water CHF to 195.3 W/cm2, a 56% increase. The water-to-Novec CHF ratio ranged from 3.6× to 5.0× across configurations.

Zitieren

APA

Mustafa, N. E., & Kandlikar, S. G. (2026). Comparative Evaluation of Subcooled Pool Boiling Performance Using Novec 7000 and Water in a Taper Microgap Boiling Chamber. ASME Journal of Heat and Mass Transfer, 148(9). https://doi.org/10.1115/1.4072138

Vancouver

Mustafa NE, Kandlikar SG. Comparative Evaluation of Subcooled Pool Boiling Performance Using Novec 7000 and Water in a Taper Microgap Boiling Chamber. ASME Journal of Heat and Mass Transfer. 2026;148(9). doi:10.1115/1.4072138

BibTeX
@article{Mustafa2026,
  author = {Mustafa, Nooruldeen E. and Kandlikar, Satish G.},
  title = {Comparative Evaluation of Subcooled Pool Boiling Performance Using Novec 7000 and Water in a Taper Microgap Boiling Chamber},
  journal = {ASME Journal of Heat and Mass Transfer},
  year = {2026},
  volume = {148},
  number = {9},
  doi = {10.1115/1.4072138}
}
Kostenlos starten →