A Grey-Box Framework for Modeling Free-Floating Indoor Temperature and Cooling Implications in Residential Buildings in Hot-Arid Regions
ASME Journal of Engineering for Sustainable Buildings and Cities · 01.05.2026 · 7 (2)
DOI: 10.1115/1.4072023 ↗Kurz gefasst
Fachartikel in der Zeitschrift ASME Journal of Engineering for Sustainable Buildings and Cities, online erschienen am 08.06.2026. Verfasst von Hamidreza Najafi und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
In the present article, a data-driven, physics-informed case study of passive thermal behavior in a two-storey residential villa located in Al Rayyan, Qatar, is presented to characterize the building's thermal response and evaluate comfort-related cooling implications. During the monitoring periods, the villa operated under free-floating conditions with no active cooling, allowing the observed indoor temperature evolution to be attributed primarily to envelope-driven heat gains associated with outdoor conditions and solar irradiation. High-resolution measurements of indoor and outdoor air temperatures and relative humidity were collected at 5-min intervals over multiple summer periods. A low-order grey-box model, formulated in a lumped-capacitance (RC) framework, is developed and validated to predict indoor air temperature dynamics using measured indoor thermal state and a diurnal solar forcing proxy that captures thermal lag effects characteristic of heavy-mass construction. The resulting model enables the time-resolved prediction of indoor temperature evolution under free-floating conditions and is subsequently applied recursively to evaluate comfort-related cooling implications associated with common indoor setpoints. The proposed grey-box framework achieved a one-step-ahead validation root-mean-square error (RMSE) of 0.083 °C and a mean absolute error (MAE) of 0.069 °C, while recursive simulations reproduced prolonged free-floating indoor temperature evolution with an average RMSE of approximately 1.16 °C over extended periods. Recursive exceedance analysis showed that indoor temperatures remained above a 25 °C comfort threshold for more than 110 h during the analyzed monitoring periods, corresponding to approximately 443 °C h of cumulative thermal exposure. The proposed framework provides a practical pathway for translating field measurements into simplified predictive models that support passive thermal assessment and cooling-related analysis in hot-arid residential buildings.
Zitieren
APA
Najafi, H., & Beitelmal, A. H. (2026). A Grey-Box Framework for Modeling Free-Floating Indoor Temperature and Cooling Implications in Residential Buildings in Hot-Arid Regions. ASME Journal of Engineering for Sustainable Buildings and Cities, 7(2). https://doi.org/10.1115/1.4072023
Vancouver
Najafi H, Beitelmal AH. A Grey-Box Framework for Modeling Free-Floating Indoor Temperature and Cooling Implications in Residential Buildings in Hot-Arid Regions. ASME Journal of Engineering for Sustainable Buildings and Cities. 2026;7(2). doi:10.1115/1.4072023
BibTeX
@article{Najafi2026,
author = {Najafi, Hamidreza and Beitelmal, AbdlMonem H.},
title = {A Grey-Box Framework for Modeling Free-Floating Indoor Temperature and Cooling Implications in Residential Buildings in Hot-Arid Regions},
journal = {ASME Journal of Engineering for Sustainable Buildings and Cities},
year = {2026},
volume = {7},
number = {2},
doi = {10.1115/1.4072023}
}
EUVIMED