EUVIMEDEUVIMED entdecken
Crossref

Development and Modeling of a Wire Straightening Mechanism for Coaxial Wire Laser-Directed Energy Deposition

Sutonu Oraon, Soham Mujumdar, Ramesh Singh

Journal of Micro and Nano Science and Engineering · 01.09.2026 · 14 (3)

DOI: 10.1115/1.4071994 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Micro and Nano Science and Engineering, online erschienen am 09.06.2026. Verfasst von Sutonu Oraon und 2 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wires with small diameters (0.1 mm–2 mm) often retain their initial curvature when uncoiled from a spool due to plastic deformation during the winding process. A wire straightening mechanism is required in various applications, such as wire laser-directed energy deposition (WLDED) and fabrication of microtools for the biomedical and semiconductor industries. In WLDED, the uncoiled wires of smaller diameters often retain residual bends and deformations, leading to feeding inconsistencies and affecting the quality of the final build. While commercial wire straighteners are effective for thicker wires, they are not adequately suited for fine wires used in WLDED. To overcome this challenge, a novel wire straightening mechanism has been developed and critically analyzed. The proposed design employs a multistage, three-point bending roller mechanism to efficiently straighten wires of varying diameters, materials, and initial curvatures. A mathematical model has been formulated to account for the initial curvature and material spring-back, enabling the prediction of the final wire shape in a three-roller bending process. The model predicts that the optimal curvature correction occurs at a certain roller actuation, which bends the wire at a particular curvature. The model identifies the number of bending stages required for curvature correction and the effect of the initial curvature on the bending process. For straightening a 1.2 mm SS 304 wire with an initial curvature of 350 mm to a final curvature of 14,359 mm, the model predicts a two-stage bending operation. The actuations in the first and second stages are 0.616 mm and 0.545 mm, respectively. For a 1.2 mm Al 4043 wire with an initial curvature of 170 mm, the model suggested a three-stage bending operation with a final radius of curvature of 13,342 mm. The model predictions and the measured values of the final curvature are in good agreement, with prediction errors ranging between 0.17% and 3.1%.

Zitieren

APA

Oraon, S., Mujumdar, S., & Singh, R. (2026). Development and Modeling of a Wire Straightening Mechanism for Coaxial Wire Laser-Directed Energy Deposition. Journal of Micro and Nano Science and Engineering, 14(3). https://doi.org/10.1115/1.4071994

Vancouver

Oraon S, Mujumdar S, Singh R. Development and Modeling of a Wire Straightening Mechanism for Coaxial Wire Laser-Directed Energy Deposition. Journal of Micro and Nano Science and Engineering. 2026;14(3). doi:10.1115/1.4071994

BibTeX
@article{Oraon2026,
  author = {Oraon, Sutonu and Mujumdar, Soham and Singh, Ramesh},
  title = {Development and Modeling of a Wire Straightening Mechanism for Coaxial Wire Laser-Directed Energy Deposition},
  journal = {Journal of Micro and Nano Science and Engineering},
  year = {2026},
  volume = {14},
  number = {3},
  doi = {10.1115/1.4071994}
}
Kostenlos starten →