EUVIMEDEUVIMED entdecken
Crossref

Theoretical Study of Heat Transfer in a Two-Channel Flat-Plate Air Solar Collector with and Without Phase Change Material

Benjamin Álvarez, Jesús Arce, Francisco López-Santos, Jesús Alonso Cruz Valdez, Daniel Montalvo, Dario Colorado-Garrido, Luis Guillermo Carreto-Hernandez

Journal of Solar Energy Engineering · 01.10.2026 · 148 (5)

DOI: 10.1115/1.4071956 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Solar Energy Engineering, online erschienen am 04.06.2026. Verfasst von Benjamin Álvarez und 6 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The heat transfer performance of a two-channel solar air collector (SAC-2C) incorporating phase change material (PCM) in the absorber plate was investigated. The collector was analyzed using one-dimensional global energy balances under unsteady conditions. The thermal evaluation of the SAC-2C was conducted considering four climatic conditions in Mexico (Mexico City, Cuernavaca, Monterrey, and Ciudad Juárez), taking into account the coldest and warmest days of each month in 2023. Additionally, the collector was tested without PCM, and four different PCMs were applied to the absorber plate with thicknesses of 0.01 m and 0.025 m. A parametric study was performed with a total of 864 analysis cases. Implementing PCM technology resulted in a decrease of up to 10.0% in the thermal efficiency of the SAC-2C. However, the PCM system manages to store energy and supply it during periods of low solar radiation. The parametric study found that the best configuration for Mexico City was the SAC-2C with a 25.0-mm-thick layer of Rubitherm 25 HC, which can provide up to 10 h of thermal comfort, has a payback period of 18 years, and prevents the emission of up to 400 kg of CO2 per year per square meter of installation. Similarly, the best configurations were found for each of the climates analyzed. Finally, it was found that PCM technology has a payback period ranging from 9 to 23 years. Considering a useful life of 27.4 years, it proves to be a viable alternative for passive building climate control.

Zitieren

APA

Álvarez, B., Arce, J., López-Santos, F., Valdez, J. A. C., Montalvo, D., Colorado-Garrido, D., & Carreto-Hernandez, L. G. (2026). Theoretical Study of Heat Transfer in a Two-Channel Flat-Plate Air Solar Collector with and Without Phase Change Material. Journal of Solar Energy Engineering, 148(5). https://doi.org/10.1115/1.4071956

Vancouver

Álvarez B, Arce J, López-Santos F, Valdez JAC, Montalvo D, Colorado-Garrido D, et al. Theoretical Study of Heat Transfer in a Two-Channel Flat-Plate Air Solar Collector with and Without Phase Change Material. Journal of Solar Energy Engineering. 2026;148(5). doi:10.1115/1.4071956

BibTeX
@article{lvarez2026,
  author = {Álvarez, Benjamin and Arce, Jesús and López-Santos, Francisco and Valdez, Jesús Alonso Cruz and Montalvo, Daniel and Colorado-Garrido, Dario and Carreto-Hernandez, Luis Guillermo},
  title = {Theoretical Study of Heat Transfer in a Two-Channel Flat-Plate Air Solar Collector with and Without Phase Change Material},
  journal = {Journal of Solar Energy Engineering},
  year = {2026},
  volume = {148},
  number = {5},
  doi = {10.1115/1.4071956}
}
Kostenlos starten →