EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Compressor Fouling Assessment By On-Field Deposit Detection on 260 MW Gas Turbine

Alessio Suman, Nicola Zanini, Annalisa Fortini, Mattia Piovan, Michele Pinelli

Journal of Engineering for Gas Turbines and Power · 01.09.2026 · 148 (9)

DOI: 10.1115/1.4071903 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Engineering for Gas Turbines and Power, online erschienen am 25.05.2026. Verfasst von Alessio Suman und 4 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compressor fouling prediction is an even more challenging task for gas turbine manufacturers and end-users, who must increase efficiency and reduce consumption while maintaining reliability and service. Land-based units and flying gas turbines are susceptible to contamination from airborne pollutants. Plant location or airport conditions determine the intensity of the exposure to such contaminants. Natural- and anthropogenic-based contaminant sources determine the intensity and characteristics of contamination, which are mitigated or enhanced by local wind and relative humidity. All of these variables interact and, depending on the machine design and performance, determine changes in the unit's performance over time. In this work, a detailed analysis of contamination experienced by a 260 MW land-based unit was conducted. The analysis comprises the on-field detection and collection of deposits taken from the filter house and the relevant surface of the compressor multistage unit. Fouling was assessed by analyzing the sample with optical and electron-scanning microscopes. The results propose the structure, morphology, and chemical composition of deposits from the inlet section to the last stage of the compressor unit. Effects such as temperature, oxidation, and contamination sources have been cross-correlated to provide a general interpretation of the data and to define guidelines for addressing the compressor fouling phenomenon.

Zitieren

APA

Suman, A., Zanini, N., Fortini, A., Piovan, M., & Pinelli, M. (2026). Compressor Fouling Assessment By On-Field Deposit Detection on 260 MW Gas Turbine. Journal of Engineering for Gas Turbines and Power, 148(9). https://doi.org/10.1115/1.4071903

Vancouver

Suman A, Zanini N, Fortini A, Piovan M, Pinelli M. Compressor Fouling Assessment By On-Field Deposit Detection on 260 MW Gas Turbine. Journal of Engineering for Gas Turbines and Power. 2026;148(9). doi:10.1115/1.4071903

BibTeX
@article{Suman2026,
  author = {Suman, Alessio and Zanini, Nicola and Fortini, Annalisa and Piovan, Mattia and Pinelli, Michele},
  title = {Compressor Fouling Assessment By On-Field Deposit Detection on 260 MW Gas Turbine},
  journal = {Journal of Engineering for Gas Turbines and Power},
  year = {2026},
  volume = {148},
  number = {9},
  doi = {10.1115/1.4071903}
}
Kostenlos starten →