Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, online erschienen am 11.05.2026. Verfasst von Shahab Azimi und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechatronic Systems Engineering, Simon Fraser University, 250-13450 102nd Avenue, Surrey, BC V3T 0A3, Canada. Hauptthemen laut MEDLINE: Particle Size, Filtration. Die Arbeit nennt 41 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Variable inhalation flow rates reduce aerosol drug efficacy, while separate devices for therapy and monitoring hinder patient adherence. This study computationally designs a novel, dual-function valve to solve these issues. Operating on inertial impaction, the valve uses a nozzle to create an aerosol jet and a movable plate to force a sharp airflow turn. Larger, high-inertia particles impact the plate, while smaller therapeutic particles remain entrained. Building on an optimized geometry, a computational fluid dynamics (CFD) model characterized valve performance across clinically relevant conditions. The model simulated aerosol transport during low-flow therapeutic inhalation (10–60 L/min) and high-flow diagnostic peak expiratory flow rate (PEFR) exhalation (100–700 L/min). A custom “valve efficacy” metric quantified selective particle filtration based on aerodynamic diameter. Filtration efficacy is highly dependent on inhalation flow rate and nozzle-to-plate distance. A high-performance therapeutic window was identified at 20–35 L/min, maintaining efficacy above 90%. A direct, linear relationship between aerodynamic drag on the plate and the optimal filtration distance was established. This enables a passive, self-regulating mechanism governed by a linear spring. Augmenting this with a second, stiffer spring in series allows the assembly to function as a PEFR meter. The computational results validate the feasibility of a single, flow-actuated valve that integrates selective therapeutic aerosol filtration with diagnostic PEFR monitoring. This design represents a significant step toward developing more personalized, effective, and user-friendly devices for managing chronic respiratory diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mechatronic Systems Engineering, Simon Fraser University, 250-13450 102nd Avenue, Surrey, BC V3T 0A3, Canada.
- Simon Fraser University.
- School of Mechatronic Systems Engineering, Simon Fraser University, Room 4174, 250-13450 102nd Avenue, Surrey, BC V3T 0A3, Canada.
ORCID-Profile: Shahab Azimi
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Azimi, S., & Arzanpour, S. (2026). Design of a Novel Dual-Function Spacer Valve for Selective Aerosol Size Filtering and Measuring Peak Expiratory Flow Rate. Journal of Biomechanical Engineering, 148(8). https://doi.org/10.1115/1.4071666
Vancouver
Azimi S, Arzanpour S. Design of a Novel Dual-Function Spacer Valve for Selective Aerosol Size Filtering and Measuring Peak Expiratory Flow Rate. Journal of Biomechanical Engineering. 2026;148(8). doi:10.1115/1.4071666
BibTeX
@article{Azimi2026,
author = {Azimi, Shahab and Arzanpour, Siamak},
title = {Design of a Novel Dual-Function Spacer Valve for Selective Aerosol Size Filtering and Measuring Peak Expiratory Flow Rate},
journal = {Journal of Biomechanical Engineering},
year = {2026},
volume = {148},
number = {8},
doi = {10.1115/1.4071666}
}
EUVIMED