Sensitivity Analysis of a Morphological Finite Element L4–L5 Functional Spine Unit for Biomechanical Responses
Journal of Biomechanical Engineering · 2026
DOI: 10.1115/1.4070766 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2026. Verfasst von Subin P George und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Design, IIT Madras, Chennai, Tamil Nadu 600036, India. Hauptthemen laut MEDLINE: Finite Element Analysis, Lumbar Vertebrae, Mechanical Phenomena. Die Arbeit nennt 39 Literaturangaben.
Abstract (Originalsprache)
Morphological models offer significant improvements over static vertebral models by providing predictive capabilities for personalized medicine and injury prevention. These models are invaluable for evaluating biomechanical implications of surgical outcomes and designing personalized rehabilitation plans. Traditional in vitro experiments are limited by the minimal shape variation in available populations. This study aims to assess the sensitivity of anthropometric features on the biomechanical responses of the L4–L5 lumbar functional spine unit (FSU) under moment loading conditions. A population of L4–L5 FSUs was generated using a Design of Experiment (DoE) framework. One Factor at a Time (OFAT) analysis at five levels and Constrained Lattice Hyper Cube Sampling (CLHS) with 200 samples were employed. Anthropometric variations in disc wedging angle, anteroposterior diameter, transverse diameter (TD), vertebral height, and facet sagittal angle were applied using ANSA BETA CAETM. Morphing operations ensured anatomical adaptability without compromising mesh quality. Sensitivity analysis was performed using Pearson's Correlation Coefficient to evaluate the relationship between anthropometric parameters and biomechanical responses, including range of motion, disc pressures, and facet contact forces (CF). Model responses were validated against in vitro experimental data to confirm biomechanical fidelity. Sensitivity analysis using linear regression coefficients identified transverse diameter (−0.99 against range of motion (ROM)), anteroposterior diameter (−0.97 against ROM), and disc wedging angle (0.90 against facet contact force) as the most influential input parameters across different loading scenarios. The Pearson correlation analysis further substantiated these findings, revealing strong linear associations between morphological variations and biomechanical responses. These trends exhibited good agreement with existing in vitro experimental data. This study highlights the importance of geometric variations in determining biomechanical responses of the L4–L5 FSU. The findings provide a framework for treatment planning, critical response prediction, and patient-specific surgical outcome evaluation, paving the way for advancements in personalized medicine and rehabilitation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Engineering Design, IIT Madras, Chennai, Tamil Nadu 600036, India.
- Indian Institute of Technology Madras.
- Department of Spine, CMC Vellore, Vellore, Tamil Nadu 632004, India.
Zitieren
APA
George, S. P., Venkatesh, K., & Kumar, G. S. (2026). Sensitivity Analysis of a Morphological Finite Element L4–L5 Functional Spine Unit for Biomechanical Responses. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4070766
Vancouver
George SP, Venkatesh K, Kumar GS. Sensitivity Analysis of a Morphological Finite Element L4–L5 Functional Spine Unit for Biomechanical Responses. Journal of Biomechanical Engineering. 2026. doi:10.1115/1.4070766
BibTeX
@article{George2026,
author = {George, Subin P and Venkatesh, Krishnan and Kumar, Gurunathan Saravana},
title = {Sensitivity Analysis of a Morphological Finite Element L4–L5 Functional Spine Unit for Biomechanical Responses},
journal = {Journal of Biomechanical Engineering},
year = {2026},
doi = {10.1115/1.4070766}
}
EUVIMED