EUVIMEDEUVIMED entdecken
Crossref

Experimental Evaluation of Exergetic and Sustainability Performances in Solar Air Heaters Using Transverse Wire Rib Roughness With Various Gaps

Dilbag Singh Mondloe, Harish Kumar Ghritlahre, Gajendra Kumar Agrawal

Journal of Solar Energy Engineering · 01.02.2026 · 148 (1)

DOI: 10.1115/1.4069860 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Solar Energy Engineering, online erschienen am 10.10.2025. Verfasst von Dilbag Singh Mondloe und 2 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 62 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This experimental study was conducted under real-time outdoor weather conditions at a site in India (latitude 19.1008 deg N, longitude 81.9818 deg E) to evaluate the second law (exergetic) efficiency of roughened solar air heaters (SAHs) using transverse wire ribs with various gap numbers (Ng = 1–4) against a smooth duct. The analysis focused on exergetic performance indicators, including exergy input (Exin), exergy output (Exout), exergy destruction (Exdest), exergetic efficiency (ηII), improvement potential (IP), and the sustainability index, with results compared against existing literature. Five SAH configurations types I–V were tested at different air mass flow-rates (m˙) ranging from 0.01891 to 0.03937 kg/s, with relative roughness pitch (P/e = 10), relative roughness height (e/D = 0.043), and duct dimensions (360 mm width, 30 mm height). The configuration with Ng = 2 at a mass flow-rate (m˙) of 0.02889 kg/s yielded the best performance, recording the highest Exin (426.57 W), Exout (9.89 W), and exergetic efficiency (3.54%). The maximum exergy destruction (422.58 W) occurred at Ng = 3 and 4, while the highest IP (418.90 W) was observed at the highest flow-rate, and the peak sustainability index (1.03669) again occurred at Ng = 2. The comparative analysis confirms that the roughened configurations notably outperform the smooth duct and show improvements over results reported in prior studies, underlining their practical potential for sustainable energy applications.

Zitieren

APA

Mondloe, D. S., Ghritlahre, H. K., & Agrawal, G. K. (2026). Experimental Evaluation of Exergetic and Sustainability Performances in Solar Air Heaters Using Transverse Wire Rib Roughness With Various Gaps. Journal of Solar Energy Engineering, 148(1). https://doi.org/10.1115/1.4069860

Vancouver

Mondloe DS, Ghritlahre HK, Agrawal GK. Experimental Evaluation of Exergetic and Sustainability Performances in Solar Air Heaters Using Transverse Wire Rib Roughness With Various Gaps. Journal of Solar Energy Engineering. 2026;148(1). doi:10.1115/1.4069860

BibTeX
@article{Mondloe2026,
  author = {Mondloe, Dilbag Singh and Ghritlahre, Harish Kumar and Agrawal, Gajendra Kumar},
  title = {Experimental Evaluation of Exergetic and Sustainability Performances in Solar Air Heaters Using Transverse Wire Rib Roughness With Various Gaps},
  journal = {Journal of Solar Energy Engineering},
  year = {2026},
  volume = {148},
  number = {1},
  doi = {10.1115/1.4069860}
}
Kostenlos starten →