EUVIMEDEUVIMED entdecken
Open Access

Deformation Response of the Human Lamina Cribrosa to Intracranial Pressure Lowering

Kelly A Clingo, Cameron A Czerpak iD, Sara Grace Ho, Megha Patel, Crystal Favorito, Anny Zheng, Abhay Moghekar, Harry A Quigley, Thao D Nguyen iD

Journal of Biomechanical Engineering · 01.07.2025 · 147 (7)

DOI: 10.1115/1.4068633 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, online erschienen am 04.06.2025. Verfasst von Kelly A Clingo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD 21218. Hauptthemen laut MEDLINE: Intracranial Pressure, Optic Disk, Mechanical Phenomena. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NEI NIH HHS, BrightFocus Foundation, National Eye Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The optic nerve head (ONH) is subjected to both intra-ocular pressure (IOP) and intracranial pressure (ICP). The translaminar pressure difference (TLPD) is defined as the difference between IOP and ICP. A change in TLPD, whether from changes in IOP or ICP, could subject the lamina cribrosa (LC) to altered deformation, potentially damaging the axons, activating the mechanosensitive glial cells, and promoting remodeling of the connective tissue structures in the ONH. In this study, we applied spectral domain optical coherence tomography (SD-OCT) and digital volume correlation (DVC) to calculate the deformation response of the LC in 7 eyes of 7 patients with normal pressure hydrocephalus (NPH). Radial SD-OCT scans centered on the ONH were acquired prior to and after therapeutic extended cerebrospinal fluid (CSF) drainage. IOP was measured immediately before imaging, and ICP was measured at the beginning and end of the drainage procedure. The procedure led to a mean ICP decrease of 11.24±1.84 mmHg and a small, nonsignificant mean IOP increase of 0.67±2.56 mmHg. ICP lowering produced a significant Ezz=−0.50%±0.47%, Err=0.53%±0.48%, and Eθz=0.35%±0.21% (p≤0.031). A larger compressive Ezz was associated with a larger ICP decrease (p=0.007). Larger Err, Erθ, maximum principal strain, Emax and maximum shear strain, Smax in the plane of the radial scans were associated with a larger increase in a calculated TLPD change (p≤0.035).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intracranial PressureOptic DiskMechanical PhenomenaHumansMaleTomography, Optical CoherenceFemaleAgedMiddle AgedIntraocular PressureHydrocephalus, Normal PressureBiomechanical Phenomena

Stichwörter der Autor:innen

biomechanics, space-associated neuro-ocular syndromeglaucomaintracranial pressureoptic nerve head

Autor:innen und Institutionen

  • Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD 21218.
  • Johns Hopkins University.
  • Department of Neurology, Johns Hopkins School of Medicine, Johns Hopkins University, Baltimore, MD 21287.
  • Johns Hopkins Medicine.
  • Johns Hopkins Hospital.
  • Johns Hopkins School of Medicine, Wilmer Eye Institute, Baltimore, MD 21287.

ORCID-Profile: Cameron A Czerpak, Thao D Nguyen

Förderung

  • NEI NIH HHS
  • BrightFocus Foundation
  • National Eye Institute

Zitieren

APA

Clingo, K. A., Czerpak, C. A., Ho, S. G., Patel, M., Favorito, C., Zheng, A., Moghekar, A., Quigley, H. A., & Nguyen, T. D. (2025). Deformation Response of the Human Lamina Cribrosa to Intracranial Pressure Lowering. Journal of Biomechanical Engineering, 147(7). https://doi.org/10.1115/1.4068633

Vancouver

Clingo KA, Czerpak CA, Ho SG, Patel M, Favorito C, Zheng A, et al. Deformation Response of the Human Lamina Cribrosa to Intracranial Pressure Lowering. Journal of Biomechanical Engineering. 2025;147(7). doi:10.1115/1.4068633

BibTeX
@article{Clingo2025,
  author = {Clingo, Kelly A and Czerpak, Cameron A and Ho, Sara Grace and Patel, Megha and Favorito, Crystal and Zheng, Anny and Moghekar, Abhay and Quigley, Harry A and Nguyen, Thao D},
  title = {Deformation Response of the Human Lamina Cribrosa to Intracranial Pressure Lowering},
  journal = {Journal of Biomechanical Engineering},
  year = {2025},
  volume = {147},
  number = {7},
  doi = {10.1115/1.4068633}
}
Kostenlos starten →