Multiphysics Simulations of a Bioprinted Pulsatile Fontan Conduit
Journal of Biomechanical Engineering · 01.07.2025 · 147 (7)
DOI: 10.1115/1.4068319 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, online erschienen am 15.05.2025. Verfasst von Zinan Hu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Stanford University, Stanford, CA 94305. Hauptthemen laut MEDLINE: Fontan Procedure, Bioprinting, Pulsatile Flow, Models, Cardiovascular. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 83 Literaturangaben.
Abstract (Originalsprache)
For single ventricle congenital heart patients, Fontan surgery is the final stage in a series of palliative procedures, bypassing the heart to enable passive flow of de-oxygenated blood from the inferior vena cava (IVC) to the pulmonary arteries. This circulation leads to severely elevated central venous pressure, diminished cardiac output, and thus numerous sequelae and premature mortality. To address these issues, we propose a bioprinted pulsatile conduit to provide a secondary power source for the Fontan circulation. A multiphysics computational framework was developed to predict conduit performance and to guide design prior to printing. Physics components included electrophysiology, cardiomyocyte contractility, and fluid-structure interaction coupled to a closed-loop lumped parameter network representing Fontan physiology. A range of myocardial contractility was considered and simulated. The initial conduit design with adult ventricular cardiomyocyte contractility values coupled to a Purkinje network demonstrated potential to reduce liver (IVC) pressure from 16.4 to 9.3 mmHg and increase cardiac output by 29%. After systematically assessing the impacts of contraction duration, fiber direction, and valve placement on conduit performance, we identified a favorable design that successfully reduces liver pressure to 7.3 mmHg and increases cardiac output by 38%, almost normalizing adverse hemodynamics in the lower venous circulation. Valves at the input and output of the conduit are essential to achieve these satisfactory results; without valves, performance is compromised. However, a potential drawback of the design is the elevation of superior vena cava (SVC) pressure, which varies linearly with liver pressure reduction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical Engineering, Stanford University, Stanford, CA 94305.
- School of Medicine, Stanford University, Stanford, CA 94305.
- Stanford Medicine.
- Department of Biomedical Engineering, Yale University, New Haven, CT 06520.
- Yale University.
- Department of Pediatrics, Stanford University, Stanford, CA 94305.
ORCID-Profile: Nir Emuna
Zitieren
APA
Hu, Z., Herrmann, J. E., Schwarz, E. L., Gerosa, F. M., Emuna, N., Humphrey, J. D., Feinberg, A. W., Hsia, T. Y., Skylar-Scott, M. A., & Marsden, A. L. (2025). Multiphysics Simulations of a Bioprinted Pulsatile Fontan Conduit. Journal of Biomechanical Engineering, 147(7). https://doi.org/10.1115/1.4068319
Vancouver
Hu Z, Herrmann JE, Schwarz EL, Gerosa FM, Emuna N, Humphrey JD, et al. Multiphysics Simulations of a Bioprinted Pulsatile Fontan Conduit. Journal of Biomechanical Engineering. 2025;147(7). doi:10.1115/1.4068319
BibTeX
@article{Hu2025,
author = {Hu, Zinan and Herrmann, Jessica E and Schwarz, Erica L and Gerosa, Fannie M and Emuna, Nir and Humphrey, Jay D and Feinberg, Adam W and Hsia, Tain-Yen and Skylar-Scott, Mark A and Marsden, Alison L},
title = {Multiphysics Simulations of a Bioprinted Pulsatile Fontan Conduit},
journal = {Journal of Biomechanical Engineering},
year = {2025},
volume = {147},
number = {7},
doi = {10.1115/1.4068319}
}
EUVIMED