Fachartikel in der Zeitschrift Journal of Medical Devices, online erschienen am 28.01.2025. Verfasst von Gang Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Medical Center, Washington, DC 20010. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic resonance imaging (MRI) can provide high contrast soft tissue visualization without ionizing radiation, which makes it an attractive imaging modality for interventional procedures. However, the strong magnetic and radio frequency (RF) fields impose significant challenges to the development of robotic systems within the magnetic resonance environment. Consequently, designing MRI-compatible actuators is crucial for advancing MRI-guided robotic systems. This paper reports the design, control, and characterization of a gear-based pneumatic stepper motor. The motor is designed with three actuating piston units and a geared rotor. The three actuating pistons are driven sequentially by compressed air to push the geared rotor and to generate bidirectional stepwise motion. Experiments were conducted to characterize the motor in terms of torque, speed, control, and MRI compatibility. The results demonstrate that the motor can deliver a maximum continuous torque of 1300 mNm at 80 pounds per square inch (PSI) (0.55 MPa) with 9 m air hoses. The closed-loop control evaluation demonstrates the steady-state error of position tracking was 0.81±0.52 deg. The MRI compatibility study indicated negligible image quality degradation. Therefore, the proposed pneumatic stepper motor can effectively serve as an actuator for MRI-guided robotic applications.

Schlagwörter

Stichwörter der Autor:innen

MR-Safe actuatorMRI-guided interventionMRI-guided robotmedical robotpneumatic stepper motor

Autor:innen und Institutionen

  • Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Medical Center, Washington, DC 20010.

ORCID-Profile: Gang Li

Förderung

  • NIBIB NIH HHS
  • National Institutes of Health

Zitieren

APA

Li, G., Yarmolenko, P., Cleary, K., & Monfaredi, R. (2025). An MR-Safe Pneumatic Stepper Motor: Design, Control, and Characterization. Journal of Medical Devices, 19(1). https://doi.org/10.1115/1.4067605

Vancouver

Li G, Yarmolenko P, Cleary K, Monfaredi R. An MR-Safe Pneumatic Stepper Motor: Design, Control, and Characterization. Journal of Medical Devices. 2025;19(1). doi:10.1115/1.4067605

BibTeX
@article{Li2025,
  author = {Li, Gang and Yarmolenko, Pavel and Cleary, Kevin and Monfaredi, Reza},
  title = {An MR-Safe Pneumatic Stepper Motor: Design, Control, and Characterization},
  journal = {Journal of Medical Devices},
  year = {2025},
  volume = {19},
  number = {1},
  doi = {10.1115/1.4067605}
}
Kostenlos starten →