Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues

Vijay Shashank Udayamohan, Achu Geetha Byju iD, Jason L Harris, Balakrishna Haridas

Journal of Biomechanical Engineering · 2025

DOI: 10.1115/1.4067084 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2025. Verfasst von Vijay Shashank Udayamohan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Texas A&M University, 9201 Warm Springs Cir, Plano, TX 75024. Hauptthemen laut MEDLINE: Stomach, Elasticity, Stress, Mechanical. Die Arbeit nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Laparoscopic staplers are used extensively to seal and transect tissue. These devices compress tissue between the stapler jaws to achieve a desired compressed tissue thickness in preparation for stapling. The extent and rate of compression are dependent on surgeon technique, tissue characteristics, and stapler type, all of which can impact stapling outcomes such as bleeding, staple line leaks, and tissue healing. Historically, surgeons have relied on their experience, training, and tactile feedback from the device to optimize stapling. In recent years, the transition to electromechanical and robotic staplers has greatly impacted the tactile feedback available to the surgeon. This raises new questions about the optimal rates of tissue compression and the resultant tissue forces. This study quantifies the transmural biomechanics of the porcine stomach wall. Multirate indentation tests were used to observe the effects of indentation rate on the viscoelastic behavior of the stomach tissue during indentation, stress relaxation, and unconstrained recovery. Results show that the stomach wall demonstrates higher stress relaxation (88% versus 80%) and greater strain recovery (52% versus 47%) when indented at high rates (37.5%/s) versus slow rates (7.5%/s). Additionally, water content analysis was used to study fluid flow away from indented regions. Unindented regions were found to have greater water content compared to indented regions (78% compared to 75%). This data generated in this study may be used to enable the development of constitutive models of stomach tissue, which in turn may inform the control algorithms that drive compressive surgical devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StomachElasticityStress, MechanicalAnimalsSwineViscosityCompressive StrengthBiomechanical PhenomenaWater

Substanzen

Water

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Texas A&M University, 9201 Warm Springs Cir, Plano, TX 75024.
  • Texas A&M University.
  • Department of Biomedical Engineering, Texas A&M University, 101 Bizzell St., 3120 TAMU, College Station, TX 77843.
  • Ethicon Endosurgery, 4545 Creek Road, Cincinnati, OH 45242.
  • Departments of Biomedical and Mechanical Engineering, Texas A&M University, 101 Bizzell St., 3120 TAMU, College Station, TX 77843.

ORCID-Profile: Achu Geetha Byju

Zitieren

APA

Udayamohan, V. S., Byju, A. G., Harris, J. L., & Haridas, B. (2025). Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4067084

Vancouver

Udayamohan VS, Byju AG, Harris JL, Haridas B. Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues. Journal of Biomechanical Engineering. 2025. doi:10.1115/1.4067084

BibTeX
@article{Udayamohan2025,
  author = {Udayamohan, Vijay Shashank and Byju, Achu Geetha and Harris, Jason L and Haridas, Balakrishna},
  title = {Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues},
  journal = {Journal of Biomechanical Engineering},
  year = {2025},
  doi = {10.1115/1.4067084}
}