EUVIMEDEUVIMED entdecken
Crossref

How Static and Cyclic Loading Affect the Mechanical Properties of the Porcine Annulus Fibrosus

Andra Neptune, John G McMorran, Diane E Gregory

Journal of Biomechanical Engineering · 2024

DOI: 10.1115/1.4065841 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2024. Verfasst von Andra Neptune und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Kinesiology and Physical Education, Wilfrid Laurier University, 75 University Avenue West, Waterloo, ON N2L 3C5, Canada. Hauptthemen laut MEDLINE: Annulus Fibrosus, Weight-Bearing, Stress, Mechanical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study sought to evaluate the effects of prolonged cyclic loading on the tissue-level mechanical properties of the spinal annulus fibrosus. Functional spinal units (FSUs) were obtained from porcine cervical spines at the C3–C4 and C5–C6 levels. Following a 15-min preload of 300 N of axial compression, the FSUs were split into three groups: the cyclic loading group cycled between 0.35 MPa and 0.95 MPa for 2 h (n = 8); the static loading group was compressed at 0.65 MPa for 2 h (n = 10); and a control group which only underwent the 300 N preload (n = 11). Following loading, samples of the annulus were excised to perform intralamellar tensile testing and interlamellar 180 deg peel tests. Variables analyzed from the intralamellar test were stress and strain at the end of the toe region, stress and strain at initial failure (yield point), Young's modulus, ultimate stress, and strain at ultimate stress. Variables evaluated from the interlamellar tests were lamellar adhesion strength, adhesion strength variability, and stiffness. The analysis showed no significant differences between conditions on any measured variable; however, there was a trend (p = 0.059) that cyclically loaded tissues had increased adhesion strength variability compared to the static and control conditions. The main finding of this study is that long-duration axial loading did not impact the intra- or interlamellar mechanical properties of the porcine annulus. A trend of increased adhesion strength variability in cyclically loaded samples could indicate a potential predisposition of the annulus to delamination.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Annulus FibrosusWeight-BearingStress, MechanicalAnimalsSwineBiomechanical PhenomenaMechanical TestsMaterials TestingTensile StrengthElastic Modulus

Autor:innen und Institutionen

  • Department of Kinesiology and Physical Education, Wilfrid Laurier University, 75 University Avenue West, Waterloo, ON N2L 3C5, Canada.
  • Department of Kinesiology and Physical Education, Wilfrid Laurier University, 75 University Avenue West, Waterloo, ON N2L 3C5, Canada; Department of Health Sciences, Wilfrid Laurier University, 75 University Avenue West…

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Neptune, A., McMorran, J. G., & Gregory, D. E. (2024). How Static and Cyclic Loading Affect the Mechanical Properties of the Porcine Annulus Fibrosus. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4065841

Vancouver

Neptune A, McMorran JG, Gregory DE. How Static and Cyclic Loading Affect the Mechanical Properties of the Porcine Annulus Fibrosus. Journal of Biomechanical Engineering. 2024. doi:10.1115/1.4065841