Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2024. Verfasst von Joseph LeSueur und 3 weiteren Autor:innen. Beteiligte Einrichtung: Joint Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, 1515 W Wisconsin Avenue, Milwaukee, WI 53233; Neur…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Blunt force trauma remains a serious threat to many populations and is commonly seen in motor vehicle crashes, sports, and military environments. Effective design of helmets and protective armor should consider biomechanical tolerances of organs in which they intend to protect and require accurate measurements of deformation as a primary injury metric during impact. To overcome challenges found in velocity and displacement measurements during blunt impact using an integrated accelerometer and two-dimensional (2D) high-speed video, three-dimensional (3D) digital image correlation (DIC) measurements were taken and compared to the accepted techniques. A semispherical impactor was launched at impact velocities from 14 to 20 m/s into synthetic ballistic gelatin to simulate blunt impacts observed in behind armor blunt trauma (BABT), falls, and sports impacts. Repeated measures Analysis of Variance resulted in no significant differences in maximum displacement (p = 0.10), time of maximum displacement (p = 0.21), impact velocity (p = 0.13), and rebound velocity (p = 0.21) between methods. The 3D-DIC measurements demonstrated equal or improved percent difference and low root-mean-square deviation compared to the accepted measurement techniques. Therefore, 3D-DIC may be utilized in BABT and other blunt impact applications for accurate 3D kinematic measurements, especially when an accelerometer or 2D lateral camera analysis is impractical or susceptible to error.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalBiomechanical PhenomenaWounds, NonpenetratingMechanical PhenomenaHumans

Autor:innen und Institutionen

  • Joint Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, 1515 W Wisconsin Avenue, Milwaukee, WI 53233; Neuroscience Research Labs, Zablocki VA Medical Center, 5000 W National Av…
  • Department of Neurosurgery, Medical College of Wisconsin, 9200 W Wisconsin Avenue, Milwaukee, WI 53226; Neuroscience Research Labs, Zablocki VA Medical Center, 5000 W National Avenue, Milwaukee, WI 53295.

ORCID-Profile: Joseph LeSueur, Narayan Yoganandan

Zitieren

APA

LeSueur, J., Koser, J., Yoganandan, N., & Pintar, F. A. (2024). Three-Dimensional-Digital Image Correlation Methodology for Kinematic Measurements of Non-Penetrating Blunt Impacts. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4065734

Vancouver

LeSueur J, Koser J, Yoganandan N, Pintar FA. Three-Dimensional-Digital Image Correlation Methodology for Kinematic Measurements of Non-Penetrating Blunt Impacts. Journal of Biomechanical Engineering. 2024. doi:10.1115/1.4065734

BibTeX
@article{LeSueur2024,
  author = {LeSueur, Joseph and Koser, Jared and Yoganandan, Narayan and Pintar, Frank A},
  title = {Three-Dimensional-Digital Image Correlation Methodology for Kinematic Measurements of Non-Penetrating Blunt Impacts},
  journal = {Journal of Biomechanical Engineering},
  year = {2024},
  doi = {10.1115/1.4065734}
}
Kostenlos starten →