Numerical Investigation on Overall Cooling Effectiveness of Narrow-Channel Double-Wall Cooling
ASME Journal of Heat and Mass Transfer · 01.08.2024 · 146 (8)
DOI: 10.1115/1.4065350 ↗Kurz gefasst
Fachartikel in der Zeitschrift ASME Journal of Heat and Mass Transfer, online erschienen am 06.05.2024. Verfasst von Guangyao Xu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Ministry of Industry and Information Technology of the People's Republic of China, National Natural Science Foundation of China, National Youth Foundation of China.
Abstract (Originalsprache)
In the double-wall cooling of turbine blades, coolant migration can lead to uneven flow distribution, which, in severe cases, can cause hot gas intrusion into the film holes, affecting the lifespan of the blade. To mitigate the negative influence of coolant migration, this study proposes a novel double-wall system called the narrow-channel double-wall cooling (NCDW) system, where thin walls are arranged inside the internal channel of double-wall cooling to achieve a more balanced coolant distribution for film holes. However, the addition of thin walls alters the flow and heat transfer distributions within the double-wall structure, ultimately affecting the overall cooling effectiveness. Therefore, numerical methods are employed in this study to analyze the flow distribution characteristics, overall cooling effectiveness, and internal heat transfer characteristics of the narrow-channel double-wall cooling. The numerical results demonstrate that narrow-channel double-wall cooling, with or without pin fins, significantly improves the uneven mass flow distribution in the film holes while maintaining an overall cooling effectiveness that is comparable to that of the double-wall effusion cooling (DWEC) system. It is worth noting that although the overall cooling effectiveness difference is slight, there are significant differences in the internal-heat-transfer characteristics between the two double-wall cooling systems. Additionally, the study discusses the influence of narrow wall thickness on the overall cooling effectiveness and flow distributions, revealing that a thinner wall can lead to higher overall cooling effectiveness in narrow-channel double-wall cooling.
Förderung
- Ministry of Industry and Information Technology of the People's Republic of China
- National Natural Science Foundation of China
- National Youth Foundation of China
Zitieren
APA
Xu, G., Du, Q., Xu, Q., Li, H., & Liu, H. (2024). Numerical Investigation on Overall Cooling Effectiveness of Narrow-Channel Double-Wall Cooling. ASME Journal of Heat and Mass Transfer, 146(8). https://doi.org/10.1115/1.4065350
Vancouver
Xu G, Du Q, Xu Q, Li H, Liu H. Numerical Investigation on Overall Cooling Effectiveness of Narrow-Channel Double-Wall Cooling. ASME Journal of Heat and Mass Transfer. 2024;146(8). doi:10.1115/1.4065350
BibTeX
@article{Xu2024,
author = {Xu, Guangyao and Du, Qiang and Xu, Qingzong and Li, Hongye and Liu, Haoyang},
title = {Numerical Investigation on Overall Cooling Effectiveness of Narrow-Channel Double-Wall Cooling},
journal = {ASME Journal of Heat and Mass Transfer},
year = {2024},
volume = {146},
number = {8},
doi = {10.1115/1.4065350}
}
EUVIMED