EUVIMEDEUVIMED entdecken
Open Access

The Lymphatic Vascular System: Does Nonuniform Lymphangion Length Limit Flow-Rate?

C D Bertram iD

Journal of Biomechanical Engineering · 2024

DOI: 10.1115/1.4065217 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2024. Verfasst von C D Bertram. Beteiligte Einrichtung: School of Mathematics and Statistics, University of Sydney, Sydney, New South Wales 2006, Australia. Hauptthemen laut MEDLINE: Models, Biological, Lymphatic Vessels. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A previously developed model of a lymphatic vessel as a chain of lymphangions was investigated to determine whether lymphangions of unequal length reduce pumping relative to a similar chain of equal-length ones. The model incorporates passive elastic and active contractile properties taken from ex vivo measurements, and intravascular lymphatic valves as transvalvular pressure-dependent resistances to flow with hysteresis and transmural pressure-dependent bias to the open state as observed experimentally. Coordination of lymphangion contractions is managed by marrying an autonomous transmural pressure-dependent pacemaker for each lymphangion with bidirectional transmission of activation signals between lymphangions, qualitatively matching empirical observations. With eight lymphangions as used here and many nonlinear constraints, the model is capable of complex outcomes. The expected flow-rate advantage conferred by longer lymphangions everywhere was confirmed. However, the anticipated advantage of uniform lymphangions over those of unequal length, compared in chains of equal overall length, was not found. A wide variety of dynamical outcomes was observed, with the most powerful determinant being the adverse pressure difference, rather than the arrangement of long and short lymphangions. This work suggests that the wide variation in lymphangion length which is commonly observed in collecting lymphatic vessels does not confer disadvantage in pumping lymph.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, BiologicalLymphatic VesselsLymphatic SystemLymphPressureMuscle Contraction

Autor:innen und Institutionen

  • School of Mathematics and Statistics, University of Sydney, Sydney, New South Wales 2006, Australia.

ORCID-Profile: C D Bertram

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Bertram, C. D. (2024). The Lymphatic Vascular System: Does Nonuniform Lymphangion Length Limit Flow-Rate?. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4065217

Vancouver

Bertram CD. The Lymphatic Vascular System: Does Nonuniform Lymphangion Length Limit Flow-Rate?. Journal of Biomechanical Engineering. 2024. doi:10.1115/1.4065217

BibTeX
@article{Bertram2024,
  author = {Bertram, C D},
  title = {The Lymphatic Vascular System: Does Nonuniform Lymphangion Length Limit Flow-Rate?},
  journal = {Journal of Biomechanical Engineering},
  year = {2024},
  doi = {10.1115/1.4065217}
}
Kostenlos starten →