Experimental and Numerical Study of Hydraulic Characteristics and Pressurization Deterioration Mechanism of a Three-Stage Mixed-Flow Electrical Submersible Pump Under Gas-Liquid Condition

Xiaoyu Dai, Qiang Xu, Chenyu Yang, Xiaobin Su, Liang Chang, Liejin Guo

Journal of Fluids Engineering · 01.09.2024 · 146 (9)

DOI: 10.1115/1.4065100 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Fluids Engineering, online erschienen am 12.04.2024. Verfasst von Xiaoyu Dai und 5 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrical submersible pump (ESP) is extensively utilized in industrial sectors such as petroleum, chemical, and nuclear energy. However, ESPs experience pressurization deterioration due to the high gas volume fraction (GVF), resulting in the pressurization failure. In this paper, a three-stage mixed-flow ESP with closed impeller structure is detailed analysis. The interstage hydraulic characteristics and pressurization deterioration mechanism of the mixed-flow ESP are investigated at various rotational speeds and inlet conditions by combining experimental and simulation. The population balance model (PBM) and renormalization group (RNG) k − ε model are employed. As the liquid flowrate increases, the ESP experiences a “three-stage” downward trend in pressurization. It is discovered that the first booster stage has a lower inflow velocity and flow separation degree compared to the subsequent booster stages, resulting in a greater liquid-phase pressurization capacity. The gas–liquid pressurization exhibits a wave-shaped downward trend due to significant deterioration in stage-wise pressurization when the liquid flowrate is low. Once the inlet gas volume fraction (IGVF) reaches the first critical GVF, the gas aggregates on the impeller's suction surface are removed at the impeller outlet, creating an annular air mass, which creates a chaotic vortex absorbing the fluids' kinetic energy.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Dai, X., Xu, Q., Yang, C., Su, X., Chang, L., & Guo, L. (2024). Experimental and Numerical Study of Hydraulic Characteristics and Pressurization Deterioration Mechanism of a Three-Stage Mixed-Flow Electrical Submersible Pump Under Gas-Liquid Condition. Journal of Fluids Engineering, 146(9). https://doi.org/10.1115/1.4065100

Vancouver

Dai X, Xu Q, Yang C, Su X, Chang L, Guo L. Experimental and Numerical Study of Hydraulic Characteristics and Pressurization Deterioration Mechanism of a Three-Stage Mixed-Flow Electrical Submersible Pump Under Gas-Liquid Condition. Journal of Fluids Engineering. 2024;146(9). doi:10.1115/1.4065100

BibTeX
@article{Dai2024,
  author = {Dai, Xiaoyu and Xu, Qiang and Yang, Chenyu and Su, Xiaobin and Chang, Liang and Guo, Liejin},
  title = {Experimental and Numerical Study of Hydraulic Characteristics and Pressurization Deterioration Mechanism of a Three-Stage Mixed-Flow Electrical Submersible Pump Under Gas-Liquid Condition},
  journal = {Journal of Fluids Engineering},
  year = {2024},
  volume = {146},
  number = {9},
  doi = {10.1115/1.4065100}
}
Kostenlos starten →