Using a Mock Circulatory Loop as a Regulatory Science Tool to Simulate Different Heart Failure Conditions
Journal of Biomechanical Engineering · 2024
DOI: 10.1115/1.4063746 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2024. Verfasst von Gavin A D'Souza und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Adminis…. Hauptthemen laut MEDLINE: Heart-Assist Devices, Cardiovascular System, Heart Failure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 74 Literaturangaben. Gefördert von: U.S. Food and Drug Administration.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
Mechanical circulatory support (MCS) device therapy is one of the primary treatment options for end-stage heart failure (HF), whereby a mechanical pump is integrated with the failing heart to maintain adequate tissue perfusion. The ISO 14708-5:2020 standard prescribes generic guidelines for nonclinical device evaluation and system performance testing of MCS devices using a mock circulatory loop (MCL). However, the utility of MCLs in premarket regulatory submissions of MCS devices is ambiguous, and the specific disease states that the device is intended to treat are not usually simulated. Hence, we aim to outline the potential of MCLs as a valuable regulatory science tool for characterizing MCS device systems by adequately representing target clinical-use HF conditions on the bench. Target pathophysiologic hemodynamics of HF conditions (i.e., cardiogenic shock (CS), left ventricular (LV) hypertrophy secondary to hypertension, and coronary artery disease), along with a healthy adult at rest and a healthy adult during exercise are provided as recommended test conditions. The conditions are characterized based on LV, aorta, and left atrium pressures using recommended cardiac hemodynamic indices such as systolic, diastolic, and mean arterial pressure, mean cardiac output (CO), cardiac cycle time, and systemic vascular resistance. This study is a first step toward standardizing MCLs to generate well-defined target HF conditions used to evaluate MCS devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993.
- Circulatory Support Devices Team, Office of Product Evaluation and Quality, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993.
Förderung
- U.S. Food and Drug Administration
Zitieren
APA
D'Souza, G. A., Rinaldi, J. E., Meki, M., Crusan, A., Richardson, E., Shinnar, M., & Herbertson, L. H. (2024). Using a Mock Circulatory Loop as a Regulatory Science Tool to Simulate Different Heart Failure Conditions. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4063746
Vancouver
D'Souza GA, Rinaldi JE, Meki M, Crusan A, Richardson E, Shinnar M, et al. Using a Mock Circulatory Loop as a Regulatory Science Tool to Simulate Different Heart Failure Conditions. Journal of Biomechanical Engineering. 2024. doi:10.1115/1.4063746
BibTeX
@article{DSouza2024,
author = {D'Souza, Gavin A and Rinaldi, Jean E and Meki, Moustafa and Crusan, Annabelle and Richardson, Eric and Shinnar, Meir and Herbertson, Luke H},
title = {Using a Mock Circulatory Loop as a Regulatory Science Tool to Simulate Different Heart Failure Conditions},
journal = {Journal of Biomechanical Engineering},
year = {2024},
doi = {10.1115/1.4063746}
}
EUVIMED