Fachartikel in der Zeitschrift Journal of Engineering and Science in Medical Diagnostics and Therapy, online erschienen am 26.09.2023. Verfasst von Blayton Padasdao und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Hawaii at Manoa, 2540 Dole St., Holmes Hall 302, Honolulu, HI 96822. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.
Abstract (Originalsprache)
The last decade has witnessed major progress in the field of minimally invasive and robotic-assisted surgeries. Needle insertion, a minimally invasive technique, has proven its efficacy in procedures such as brachytherapy, ablation, drug delivery, and biopsy. Manual needle steering inside tissue is a challenging task due to complex needle-tissue interactions, needle and tissue movement, lack of actuation and control, as well as poor sensing and visualization. Recently, active tendon-driven notched needles, and robotic manipulation systems have been proposed to assist surgeons to guide the needles in desired trajectories toward target positions. This work introduces a new deflection model for the active tendon-driven notched needle steering inside soft tissue for intention to use in model-based robotic control. The model is developed to predict needle deflection in a single-layer tissue. To validate the proposed deflection model, five sets of needle insertion experiments with a bevel-tipped active needle into single-layer phantom tissues were performed. A real-time robot-assisted ultrasound tracking method was used to track the needle tip during needle insertion. It was shown that the model predicts needle deflection with an average error of 0.58 ± 0.14 mm for the bevel-tipped active needle insertion into a single-layer phantom tissue.
Autor:innen und Institutionen
- Department of Mechanical Engineering, University of Hawaii at Manoa, 2540 Dole St., Holmes Hall 302, Honolulu, HI 96822.
Förderung
- NIBIB NIH HHS
Zitieren
APA
Padasdao, B., & Konh, B. (2024). A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue. Journal of Engineering and Science in Medical Diagnostics and Therapy, 7(1). https://doi.org/10.1115/1.4063205
Vancouver
Padasdao B, Konh B. A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue. Journal of Engineering and Science in Medical Diagnostics and Therapy. 2024;7(1). doi:10.1115/1.4063205
BibTeX
@article{Padasdao2024,
author = {Padasdao, Blayton and Konh, Bardia},
title = {A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue},
journal = {Journal of Engineering and Science in Medical Diagnostics and Therapy},
year = {2024},
volume = {7},
number = {1},
doi = {10.1115/1.4063205}
}
EUVIMED