EUVIMEDEUVIMED entdecken
Open Access

A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue

Blayton Padasdao, Bardia Konh

Journal of Engineering and Science in Medical Diagnostics and Therapy · 01.02.2024 · 7 (1)

DOI: 10.1115/1.4063205 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Engineering and Science in Medical Diagnostics and Therapy, online erschienen am 26.09.2023. Verfasst von Blayton Padasdao und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Hawaii at Manoa, 2540 Dole St., Holmes Hall 302, Honolulu, HI 96822. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The last decade has witnessed major progress in the field of minimally invasive and robotic-assisted surgeries. Needle insertion, a minimally invasive technique, has proven its efficacy in procedures such as brachytherapy, ablation, drug delivery, and biopsy. Manual needle steering inside tissue is a challenging task due to complex needle-tissue interactions, needle and tissue movement, lack of actuation and control, as well as poor sensing and visualization. Recently, active tendon-driven notched needles, and robotic manipulation systems have been proposed to assist surgeons to guide the needles in desired trajectories toward target positions. This work introduces a new deflection model for the active tendon-driven notched needle steering inside soft tissue for intention to use in model-based robotic control. The model is developed to predict needle deflection in a single-layer tissue. To validate the proposed deflection model, five sets of needle insertion experiments with a bevel-tipped active needle into single-layer phantom tissues were performed. A real-time robot-assisted ultrasound tracking method was used to track the needle tip during needle insertion. It was shown that the model predicts needle deflection with an average error of 0.58 ± 0.14 mm for the bevel-tipped active needle insertion into a single-layer phantom tissue.

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Hawaii at Manoa, 2540 Dole St., Holmes Hall 302, Honolulu, HI 96822.

Förderung

  • NIBIB NIH HHS

Zitieren

APA

Padasdao, B., & Konh, B. (2024). A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue. Journal of Engineering and Science in Medical Diagnostics and Therapy, 7(1). https://doi.org/10.1115/1.4063205

Vancouver

Padasdao B, Konh B. A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue. Journal of Engineering and Science in Medical Diagnostics and Therapy. 2024;7(1). doi:10.1115/1.4063205

BibTeX
@article{Padasdao2024,
  author = {Padasdao, Blayton and Konh, Bardia},
  title = {A Model to Predict Deflection of an Active Tendon-Driven Notched Needle Inside Soft Tissue},
  journal = {Journal of Engineering and Science in Medical Diagnostics and Therapy},
  year = {2024},
  volume = {7},
  number = {1},
  doi = {10.1115/1.4063205}
}
Kostenlos starten →