EUVIMEDEUVIMED entdecken
Crossref

Effect of Rib Blockage Ratio and Arrangements on Impingement Heat Transfer in Double-Wall Cooling

Dehai Kong, Zhenyuan Ma, Wei Li, Tao Guo, Cunliang Liu

ASME Journal of Heat and Mass Transfer · 01.09.2023 · 145 (9)

DOI: 10.1115/1.4062566 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ASME Journal of Heat and Mass Transfer, online erschienen am 31.05.2023. Verfasst von Dehai Kong und 4 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A numerical study was conducted on the multiple jet impingement heat transfer of the double-wall cooling with high blockage ratio ribs of various configurations. Three different blockage ratios (BR = 0.2, 0.3, and 0.5) and two rib arrangements relative to the effusion holes (l/Sx = 0.25 and 0.75) were thoroughly examined using the RANS method with the SST–KIC turbulence model, considering the Kato–Launder modification (K), intermittency (I), and crossflow (C) transition effects. The ratio of jet-to-target plate spacing to jet diameter (H/d) was fixed to be 1, and Reynolds numbers varied in the range of 4000–16,000. Furthermore, the computed data on the rib roughed wall were also compared with those on a flat plate for the double-wall cooling. The results demonstrate that the installation of the high blockage ribs significantly decreases the detrimental crossflow effect due to the blockage effect of the ribs and intensively disturbs the jet flow in flow passing over the ribs, thereby enhancing the heat transfer performance. For the impingement/effusion cooling, the arrangement of the rib downstream of the effusion holes (l/Sx = 0.25) shows more advantages, and the heat transfer level rises quickly as BR increases. The best thermal-hydraulic performance and heat transfer uniformity on the rib roughed target plate is both obtained at BR = 0.3, which can be increased by up to 10% and 8%, respectively, compared to those on the flat plate.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Kong, D., Ma, Z., Li, W., Guo, T., & Liu, C. (2023). Effect of Rib Blockage Ratio and Arrangements on Impingement Heat Transfer in Double-Wall Cooling. ASME Journal of Heat and Mass Transfer, 145(9). https://doi.org/10.1115/1.4062566

Vancouver

Kong D, Ma Z, Li W, Guo T, Liu C. Effect of Rib Blockage Ratio and Arrangements on Impingement Heat Transfer in Double-Wall Cooling. ASME Journal of Heat and Mass Transfer. 2023;145(9). doi:10.1115/1.4062566

BibTeX
@article{Kong2023,
  author = {Kong, Dehai and Ma, Zhenyuan and Li, Wei and Guo, Tao and Liu, Cunliang},
  title = {Effect of Rib Blockage Ratio and Arrangements on Impingement Heat Transfer in Double-Wall Cooling},
  journal = {ASME Journal of Heat and Mass Transfer},
  year = {2023},
  volume = {145},
  number = {9},
  doi = {10.1115/1.4062566}
}
Kostenlos starten →