EUVIMEDEUVIMED entdecken
Open Access

Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response

Mirle Pena, Dylan T Neu, H Amy Feng, Duane R Hammond, Kenneth R Mead, Rupak K Banerjee

Journal of Medical Devices · 01.03.2023 · 17 (1)

DOI: 10.1115/1.4056694 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Devices, online erschienen am 31.01.2023. Verfasst von Mirle Pena und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinn…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Emergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, “Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study,” Lancet Pub. Health, 5(9), pp. e475–e483; Brown et al., 2021, “Risk for Acquiring Coronavirus Disease Illness Among Emergency Medical Service Personnel Exposed to Aerosol-Generating Procedures,” Emer. Infect. Disease J., 27(9), p. 2340). The use of protective equipment may reduce, but does not eliminate their risk of becoming infected as a result of these exposures. Prehospital environments have a high risk of disease transmission exposing EMS providers to bioaerosols and droplets from infectious patients. Field intubation procedures may be performed causing the generation of bioaerosols, thereby increasing the exposure of EMS workers to pathogens. Additionally, ambulances have a reduced volume compared to a hospital treatment space, often without an air filtration system, and no control mechanism to reduce exposure. This study evaluated a containment plus filtration intervention for reducing aerosol concentrations in the patient module of an ambulance. Aerosol concentration measurements were taken in an unoccupied research ambulance at National Institute for Occupational Safety and Health (NIOSH) Cincinnati using a tracer aerosol and optical particle counters (OPCs). The evaluated filtration intervention was a containment pod with a high efficiency particulate air (HEPA)-filtered extraction system that was developed and tested based on its ability to contain, capture, and remove aerosols during the intubation procedure. Three conditions were tested (1) baseline (without intervention), (2) containment pod with HEPA-1, and (3) containment pod with HEPA-2. The containment pod with HEPA-filtered extraction intervention provided containment of 95% of the total generated particle concentration during aerosol generation relative to the baseline condition, followed by rapid air cleaning within the containment pod. This intervention can help reduce aerosol concentrations within ambulance patient modules while performing aerosol-generating procedures.

Autor:innen und Institutionen

  • Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226; Department of Biomedical Engineering, University of Cin…
  • Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH 45226.
  • Department of Mechanical and Biomedical Engineering, University of Cincinnati, 593 Rhodes Hall, 2600 Clifton Ave, Cincinnati, OH 45221.

Zitieren

APA

Pena, M., Neu, D. T., Feng, H. A., Hammond, D. R., Mead, K. R., & Banerjee, R. K. (2023). Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response. Journal of Medical Devices, 17(1). https://doi.org/10.1115/1.4056694

Vancouver

Pena M, Neu DT, Feng HA, Hammond DR, Mead KR, Banerjee RK. Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response. Journal of Medical Devices. 2023;17(1). doi:10.1115/1.4056694

BibTeX
@article{Pena2023,
  author = {Pena, Mirle and Neu, Dylan T and Feng, H Amy and Hammond, Duane R and Mead, Kenneth R and Banerjee, Rupak K},
  title = {Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response},
  journal = {Journal of Medical Devices},
  year = {2023},
  volume = {17},
  number = {1},
  doi = {10.1115/1.4056694}
}