EUVIMEDEUVIMED entdecken
Crossref

A Numerical Study on Mechanical Effects of Low-Intensity Pulsed Ultrasound on Trabecular Bone and Osteoblasts

Congbiao Tian, Haiying Liu, Chaohui Zhao, Chunqiu Zhang, Wei Wang

Journal of Biomechanical Engineering · 2023

DOI: 10.1115/1.4056658 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2023. Verfasst von Congbiao Tian und 4 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Techno…. Hauptthemen laut MEDLINE: Cancellous Bone, Osteoporosis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The lack of sufficient mechanical stimulation to the human bone, results in disuse osteoporosis. Low-intensity pulsed ultrasound (LIPUS) promotes fracture healing and the treatment of disuse osteoporosis, but its biomechanical mechanism remains unknown. Simulative research on the mechanical effects of LIPUS on disuse trabecular bone and osteoblasts have been performed. The von Mises stress of disuse trabecular bone and osteoblasts obviously increased under LIPUS irradiation. The average von Mises stress of osteoblasts were two orders of magnitude higher under the irradiation of simulant LIPUS than that without LIPUS irradiation, and the von Mises stress of osteoblasts was positively correlated with the amplitude of sound pressure excitation. The results showed that LIPUS irradiation could obviously improve the mechanical micro-environment of trabecular bone and osteoblasts to alleviate the lack of mechanical stimulation. The results of the research can reveal the biomechanical mechanism of LIPUS in the treatment of disuse osteoporosis to some extent and provide theoretical guidance for clinical treatment of disuse osteoporosis through physical methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cancellous BoneOsteoporosisHumansOsteoblastsUltrasonic WavesFracture Healing

Stichwörter der Autor:innen

disuse osteoporosislow-intensity pulsed ultrasoundnumerical simulationosteoblasttrabecular bone

Autor:innen und Institutionen

  • Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin 300384, China; National Demonstration Center for Experim…
  • Department of Mechanics, School of Mechanical Engineering, Tianjin University, Tianjin 300354, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Tian, C., Liu, H., Zhao, C., Zhang, C., & Wang, W. (2023). A Numerical Study on Mechanical Effects of Low-Intensity Pulsed Ultrasound on Trabecular Bone and Osteoblasts. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4056658

Vancouver

Tian C, Liu H, Zhao C, Zhang C, Wang W. A Numerical Study on Mechanical Effects of Low-Intensity Pulsed Ultrasound on Trabecular Bone and Osteoblasts. Journal of Biomechanical Engineering. 2023. doi:10.1115/1.4056658

BibTeX
@article{Tian2023,
  author = {Tian, Congbiao and Liu, Haiying and Zhao, Chaohui and Zhang, Chunqiu and Wang, Wei},
  title = {A Numerical Study on Mechanical Effects of Low-Intensity Pulsed Ultrasound on Trabecular Bone and Osteoblasts},
  journal = {Journal of Biomechanical Engineering},
  year = {2023},
  doi = {10.1115/1.4056658}
}
Kostenlos starten →